259
⿎
System Offset
This screen specifies the offset of marking position and laser power to the all registered files.
The functions are applicable to adjust the difference of laser power or displacement between laser marker and works in
case multiple production lines are used.
Item and Description
3
Laser Power :
Laser power offset. Offset the value of laser power set in each file.
Setting Range
50 to 200%
Reference
•
The laser power offset refers to the function to correct not the maximum laser power [W] value, but the laser power
setting value.
• “100” is specified if the value of “laser power (system offset)” × “laser power (laser setting)” is 100 or more.
4
Rotation Offset :
Rotates the object to the rotation direction around the original point.
Setting Range
-180.00 to +180.00 degree
+Y
-Y
+X
-X
Rotation (+) Rotation (-)
5
X/Y Offset :
Shifts the marking position to the X/Y direction.
Setting Range
-45.000 to +45.000 mm
(LP-V10)
-55.000 to +55.000 mm
(LP-430 / LP-420 / LP-410)
-80.000 to +80.000 mm
(LP-435 / LP-425 / LP-V15)
-27.500 to +27.500 mm
(LP-431 / LP-421 / LP-411 / LP-W052)
6
X/Y Scale :
Sets the offset scale of marking field (X and Y). Area is corrected by inputting magnification.
Setting Range
70.000 to 130.000%
Reference
•
System offset is not offset on the image display.
• When marking data is inside of marking field on image display screen and the error “Existed marking data outside of
marking field” is displayed. Check the setting value in system offset.
ME-LP400V-OP-6
Summary of Contents for LP-400 Series
Page 11: ...11 MEMO ME LP400V OP 6 ...
Page 32: ...32 1 Product Overview ME LP400V OP 6 ...
Page 58: ...2 Installation and Connection ME LP400V OP 6 ...
Page 77: ...3 Basic Operation Procedure ME LP400V OP 6 ...
Page 121: ...4 Description of Operation Screen ME LP400V OP 6 ...
Page 146: ...146 Symbol ME LP400V OP 6 ...
Page 271: ...271 MEMO ME LP400V OP 6 ...
Page 272: ...Maintenance ME LP400V OP 6 ...
Page 291: ...Troubleshooting ME LP400V OP 6 ...
Page 308: ...Appendix ME LP400V OP 6 ...
Page 328: ...Index ME LP400V OP 6 ...
Page 333: ...No 9000 0062 14V ...
Page 334: ... Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 14V ...