208
⿎
Straight Line
Description
Start Point of X/Y :
End Point of X/Y :
Specifies the starting / ending point of the straight line.
Setting Range
-45.000 to +45.000 mm
(LP-V10)
-55.000 to +55.000 mm
(LP-430 / LP-420 / LP-410)
-80.000 to +80.000 mm
(LP-435 / LP-425 / LP-V15)
-27.500 to +27.500 mm
(LP-431 / LP-421 / LP-411 / LP-W052)
Setting example of the straight line
5
15 X [mm]
0
3
10
Y [mm]
(X,Y)=(15,10)
(X,Y)=(5,3)
End Point
Start Point
ME-LP400V-OP-6