290
⿎
Detaching Method of Batteries
In case of disposal of laser marker in the European Union, remove the battery with the following procedures and
segregate it properly in accordance with the EU Battery Directive (2006/66/EC).
WARNING
•
When detaching the exhausted battery, be sure to disconnect the controller
power cable so that the power cannot be supplied to the device. There is a risk
of electrical shock.
Notice
•
This method is never described with the replacing method of the battery. The customer should call our service
representative to replace the battery.
1.
Remove the side cover of the controller.
Remove 6 screws of the side cover as shown in the figure below, and then slide the cover backward.
After removing the cover, the battery is installed in the position as shown in the right figure below (surrounded with
circle).
2.
Remove the used battery as shown in the figure below.
Cut 2 banding bands by using the nipper. Then, remove the connector of the battery, and remove the battery from the
board.
Battery
Tie Band
ME-LP400V-OP-6
Summary of Contents for LP-400 Series
Page 11: ...11 MEMO ME LP400V OP 6 ...
Page 32: ...32 1 Product Overview ME LP400V OP 6 ...
Page 58: ...2 Installation and Connection ME LP400V OP 6 ...
Page 77: ...3 Basic Operation Procedure ME LP400V OP 6 ...
Page 121: ...4 Description of Operation Screen ME LP400V OP 6 ...
Page 146: ...146 Symbol ME LP400V OP 6 ...
Page 271: ...271 MEMO ME LP400V OP 6 ...
Page 272: ...Maintenance ME LP400V OP 6 ...
Page 291: ...Troubleshooting ME LP400V OP 6 ...
Page 308: ...Appendix ME LP400V OP 6 ...
Page 328: ...Index ME LP400V OP 6 ...
Page 333: ...No 9000 0062 14V ...
Page 334: ... Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 14V ...