211
⿎
Common
1
2
3
4
5
Common Setting Item
1
Proc. Cond. No. (Processing Condition No.) :
Specifies up to 8 processing condition per one registered file.
Setting Range
0 to 7
2
X/Y Offset :
Shifts the marking position to the X or Y direction.
Setting Range
-45.000 to +45.000 mm
(LP-V10)
-55.000 to +55.000 mm
(LP-430 / LP-420 / LP-410)
-80.000 to +80.000 mm
(LP-435 / LP-425 / LP-V15)
-27.500 to +27.500 mm
(LP-431 / LP-421 / LP-411 / LP-W052)
3
Rotation Angle :
Rotates the object to the rotation direction around the origin.
Setting Range
-180.00 to +180.00 degree
4
Laser Power Correction :
Scan Speed Correction :
Laser Pulse Cycle Correction (Only LP-V series) :
Correction of the processing elements in the selected processing condition No. for the laser power / scan speed /
laser pulse cycle set at laser setting.
If the correction rate is set to 0%, the marking image is displayed in gray and marking is not executed.
Setting Range of Laser Power Correction
0 to 200%
Setting Range of Scan Speed Correction
5 to 500%
Setting Range of Laser Pulse Cycle Correction
50 to 200%
5
Area No. :
Displayed when marking on-the-fly is set in “Trigger setting”.
It indicates the order of the marking field for the concatenated marking to flying object.
Setting Range
0 to 15
ME-LP400V-OP-6
Summary of Contents for LP-400 Series
Page 11: ...11 MEMO ME LP400V OP 6 ...
Page 32: ...32 1 Product Overview ME LP400V OP 6 ...
Page 58: ...2 Installation and Connection ME LP400V OP 6 ...
Page 77: ...3 Basic Operation Procedure ME LP400V OP 6 ...
Page 121: ...4 Description of Operation Screen ME LP400V OP 6 ...
Page 146: ...146 Symbol ME LP400V OP 6 ...
Page 271: ...271 MEMO ME LP400V OP 6 ...
Page 272: ...Maintenance ME LP400V OP 6 ...
Page 291: ...Troubleshooting ME LP400V OP 6 ...
Page 308: ...Appendix ME LP400V OP 6 ...
Page 328: ...Index ME LP400V OP 6 ...
Page 333: ...No 9000 0062 14V ...
Page 334: ... Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 14V ...