Setting Value for AUTO Set
When pressing “AUTO” button after setting bar code and referential module width for the following code symbols, GS1
DataBar, GS1 DataBar Truncated, GS1 DataBar Stacked, GS1 DataBar Stacked Omnidirectional, GS1 DataBar Limited,
GS1 DataBar Expanded, GS1 DataBar Expanded Stacked, the following setting value is set automatically with each “W”
(Width) be used as the reference for calculating the setting value.
Setting Screen
Setting Item
GS1 DataBar/GS1 DataBar Truncated
Bar Code Condition
Bar Code Height
33W
Separator Pattern Height/(W) Ratio *
1
Quiet/(W) Ratio *
1
Inversion
Inversion
Guard
Available
Human Readable Text
Available
(Character Height: 6W, Character Width: 5W,
Character Interval: 4.5W, Line Feed: None *, Line
Interval: 7.5W *)
Composite Row Height *
2W
Rows Number *
0 (minimization)
Laser Setting
Line Width
LP-400 series: half of the “Module width”
LP-V/LP-W series: half of the “line width” initial value
Marking Pitch
LP-400 series: half of the “Module width”
LP-V/LP-W series: same value with the “line width”
initial value
Marking Quality Adjustment
-Wait Adjustment
10
* This setting item is set automatically when selecting GS1 DataBar CC-A, CC-B.
Setting Screen
Setting Item
GS1 DataBar Stacked
GS1 DataBar Stacked
Omnidirectional
Bar Code Condition
Bar Code Height
7W
33W
Separator Pattern Height/(W) Ratio *
―
1
Quiet/(W) Ratio *
1
Inversion
Inversion
Guard
Available
Human Readable Text
Available
(Character Height: 6W, Character Width: 5W,
Character Interval: 4.5W, Line Feed: None *, Line
Interval: 7.5W *)
Composite Row Height *
2W
Rows Number *
0 (minimization)
Laser Setting
Line Width
LP-400 series: half of the “Module width”
LP-V/LP-W series: half of the “line width” initial value
Marking Pitch
LP-400 series: half of the “Module width”
LP-V/LP-W series: same value with the “line width”
initial value
Marking Quality Adjustment
-Wait Adjustment
10
* This setting item is set automatically when selecting GS1 DataBar CC-A, CC-B.
ME-LP400V-OP-6
Summary of Contents for LP-400 Series
Page 11: ...11 MEMO ME LP400V OP 6 ...
Page 32: ...32 1 Product Overview ME LP400V OP 6 ...
Page 58: ...2 Installation and Connection ME LP400V OP 6 ...
Page 77: ...3 Basic Operation Procedure ME LP400V OP 6 ...
Page 121: ...4 Description of Operation Screen ME LP400V OP 6 ...
Page 146: ...146 Symbol ME LP400V OP 6 ...
Page 271: ...271 MEMO ME LP400V OP 6 ...
Page 272: ...Maintenance ME LP400V OP 6 ...
Page 291: ...Troubleshooting ME LP400V OP 6 ...
Page 308: ...Appendix ME LP400V OP 6 ...
Page 328: ...Index ME LP400V OP 6 ...
Page 333: ...No 9000 0062 14V ...
Page 334: ... Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 14V ...