60
•
Removing the dust and smoke
Remove any dust and smoke from the laser emission port and laser beam path using a dust collector. For effective dust
collection, put the suction port of the dust collector near the lasing part. In an environment where dust and smoke that
tend to attach to the lens surface, it is recommended to create a compression air flow to ensure thorough dust collection.
In such situation, clean the laser emission port regularly.
BCD
ABCD
BCD
Compressed Air
Dust Collector
•
Protection against electrical noise
If there are devices that generate electrical noise such as a motor or the objects that generate static electricity around
the laser marker, the laser marker can be damaged by the noise.
Securely ground the frame ground terminal of the laser marker.
Depending on the grounding environment, use the noise cut-off transformer or uninterruptible power supply system.
Position of the frame ground terminals
LP-400 series
Controller
LP-V/LP-W series
Controller
LP-V/LP-W series
Head
ME-LP400V-OP-6
Summary of Contents for LP-400 Series
Page 11: ...11 MEMO ME LP400V OP 6 ...
Page 32: ...32 1 Product Overview ME LP400V OP 6 ...
Page 58: ...2 Installation and Connection ME LP400V OP 6 ...
Page 77: ...3 Basic Operation Procedure ME LP400V OP 6 ...
Page 121: ...4 Description of Operation Screen ME LP400V OP 6 ...
Page 146: ...146 Symbol ME LP400V OP 6 ...
Page 271: ...271 MEMO ME LP400V OP 6 ...
Page 272: ...Maintenance ME LP400V OP 6 ...
Page 291: ...Troubleshooting ME LP400V OP 6 ...
Page 308: ...Appendix ME LP400V OP 6 ...
Page 328: ...Index ME LP400V OP 6 ...
Page 333: ...No 9000 0062 14V ...
Page 334: ... Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 14V ...