41
Installation Manual
Locations where Network Adaptor cannot be Mounted
flammable gases, chemicals or fire.
by qualified personnel.
6. Mounting of Network Adaptor
6-1. Location
The Network Adaptor is a wall-mounted product for indoor use. Determine the installation location in accordance with
the conditions outlined in this manual.
● Do not install it in places where there is a lot of humidity such as outdoors or in bathrooms.
● The work must be performed
● Do not install the product in the special locations listed below.
■
Standard Mounting Location of the Network Adaptor
Installation location
Indoor
Operating temperature range [°C]
0 to 40 °C
Operating humidity [% RH]
0 to 80% RH (No dew condensation)
Maximum atmospheric pressure/altitude
Lower than 1000 m above sea level
■
Special
x Locations exposed to direct sunlight.
x Locations exposed to rain or drops of water.
x Locations exposed to or potentially exposed to excessive steam, oil vapour, smoke, dust, corrosive substances, explosive/
x Locations subject to vibrations or shocks.
x Locations in the proximity of equipment/devices that are susceptible to radio interference, or locations that are emitting powerful
radio waves.
x Locations where wall mounting is not possible.
■
Mounting Position
Mount the Network Adaptor so that it is not tilted, and position the Lid release button so that is at the bottom.
Lid release button
■
Clearance Space for the Installation Location
The mounting location must have the clearance space described below for installation and maintenance.
* If one side only has a minimal clearance space, make sure to allocate more space on the other side.
10 mm or longer
300 mm or longer
50 mm
or longer
50 mm
or longer
500 mm or longer
■
Preparation for the Installation Location
<Exposed installation> Drill holes into the wall and align them with the
wiring holes on the main body.
<Semi-embedded installation> Drill holes into the wall for semi-embedded
installation.
* Provide adequate reinforcement if the
strength of the wall is
Wall machining dimensions for semi-
embedded installation
Semi-embedded depth 30 mm
Wall
135mm
310m
m
●
Location Check
The mounting position is as described in this manual.
The mounting location is not in the location listed "special locations."
The Network Adaptor is mounted in the correct orientation.
mounting space has been allocated.
The mounting surface is not inclined.
The mounting location has undergone the pre-mounting preparatory processing.