48
Installation Manual
2) Cable types
CAT5e (10BASE-T/100BASE-TX)
3) Mounting the terminal cover
Hook the terminal cover at the bottom of the power supply unit and secure it with screws from the front.
[Tightening torque 1.2 N•m]
Terminal cover
4) Completely remove foreign objects such as scrap wires.
* Attach the lid if there is some length of time before the test run after the wiring has been completed.
(How to install the front lid See 6-2 3) Attaching the lid)
●
Connection Check
The power is turned OFF.
The PE wire is connected and grounded securely.
The covered insulation of the wiring are not damaged.
The cable wire types and sizes are correct.
The wires have been processed as
and are connected securely.
No mistakes in the wiring.
The connecting length of the PE wire to the GRID terminal is longer than that of the LINE wire.
The cable is secured with an insulating lock.
The terminal cover is attached.
No foreign objects such as scrap wires.