34
Installation Manual
2) How to retract cables from the cable glands
* See 1-1. Power and Communication Line Configuration for the cable details.
■
Preparation
Be sure to turn OFF the protection device for the Lithium-ion storage battery system, the Stand-alone breaker and
DC protector.
Be sure there is no voltage at all of the terminals.
■
Retracting the Cable
Check the outer diameter of the cables and feed it through the
cable glands.
1) Applicable cable
sizes for the cable glands
Cable Gland
Applicable Cable
Diameter (mm)
Specified Cable
CT
PVC Flexible Cable 2C 0.75 mm
2
PVC Flexible Cable 2C 0.75 mm
2
PVC Flexible Cable 2C 0.75 mm
2
CAT5e (10BASE-T/100BASE-TX)
PVC Circular Cable 2C+E 2.5 mm
2
PVC Circular Cable 2C+E 2.5 mm
2
COM
SYS
DRM
GRID-INTERACTIVE
STAND-ALONE
Φ5 - Φ10
Φ5 - Φ10
Φ5 - Φ10
Φ5 - Φ10
Φ6 - Φ12
Φ6 - Φ12
* Please use copper wire cables.
(1) Push the rubber seal of cable
gland surface with a screw driver
from the bottom side of the
enclosure gently.
Put screw driver toward the inner
edge and break the rubber seal
from the inside.
(2) The screw driver tip will
come out when the rubber
seal is broken through.
Then press the seal horizontally
to the unopened parts to enlarge
the open area.
(3) When the rubber seal is almost
open, tear it up with your hands
slightly.
Now you have an open seal.
Then remove the burr around the
cap nut.
This procedure is performed only where necessary.
Rubber seal
Rubber seal
Screw Driver
Cap nut