Page 3-9
CHANGING THE
PRODUCTION BOARDS
3
193C-E-EMA03-A01-01
Positioning and Lift Transfer Rail Width Adjustment
3-2-3
Setting the Board Under Holder Plate on the Movable Side
Set the board under holder plate on the movable side which is removed at the procedure 3-2-1.
1.
Turn off the servo switch.
2.
Set the board under holder plate on
the movable side to the conveyor on
that side.
• Fix the lower part of plate with two of M3 bolts.
• Set the under holder plate so that the gap
between it and the clamp plate on the movable
side gets 1 mm to 2 mm.
• Set it not to shield the under holder interlock
sensor attached to the conveyor on the mov-
able side.
OFF ( ) ON ( )
SERVO
Board under holder
plate on movable side
M3 bolts