Application
LAN Side Port Number
WAN Side Port Number
HTTPS
Data Transmission Protocol
(HTTPS) Port No. for SIP-MLT
(Use the same value as in step
"Programming the KX-NS1000 with
Built-in Media Relay Gateway".)
NAT - SIP-MLT Data Download
Server (HTTPS) Port No.
(Use the same value as in step
"Programming the KX-NS1000 with
Built-in Media Relay Gateway".)
NTP
123
NAT - NTP Server Port No.
(Use the same value as in step
"Programming the KX-NS1000 with
Built-in Media Relay Gateway".)
RTP (UDP)
Start/End RTP (UDP) Port No.
(Use port numbers that are in the
range of the RTP ports that the
KX-NS1000 uses.)
Start/End RTP (UDP) Port No.
(Use port numbers th
at are in the
range of the RTP ports that the
KX-NS1000 uses.)
Make sure the RTP Start Port (UDP) and the RTP End Port (UDP) specified
for the router are in the range of the RTP ports that the KX-NS1000 uses.
For the range of RTP port numbers that the KX-NS1000 uses, refer to "Port
Numbers for Optional DSP Cards" in "8.5 Port Security".
*1
The port number for NTP that the KX-NS1000 uses is fixed to 123.
*2
The port number ranges must be within the range of RTP/RTCP for NAT traversal (16000–18047).
Up to 4 IP addresses can be assigned to the KX-NS1000's optional DSP cards. The following example shows the port number ranges
set for each IP address:
[Example]
Port forward destination
Port number range
DSP#1–1
16000–16511
DSP#1–2
16512–17023
DSP#2–1
17024–17535
DSP#2–2
17536–18047
Installing KX-NT500 series IP-PTs at a remote site with Built-in Media Relay
Gateway
You can install KX-NT500 series IP-PTs at the remote site directly or from the local site as follows.
1.
Register the IP-PT. For details, refer to "5.9.1 Registering IP Telephones".
2.
Programme the settings for the IP-PT.
a.
Click
Setup
®
PBX Configuration
®
Configuration
®
Slot
.
b.
Click
Virtual
®
V-IPEXT32
.
c.
Move the mouse pointer over the V-IPEXT32 card (Virtual 32-Channel VoIP Extension Card).
A menu will be shown under the mouse pointer.
d.
Click
Port Property
.
e.
Click the
Remote Place
tab.
f.
Configure the items shown below.
•
Change the value to
Remote (MRG)
for
Phone Location
.
g.
Click
OK
.
3.
Unplug the AC adaptor of the IP-PT, and then plug it in again to reboot the IP-PT manually. The IP-PT will
download settings automatically.
300
Installation Manual
5.9.4 Installing IP Phones at a Remote Site with a Built-in Media Relay Gateway
Summary of Contents for KX-NS1000
Page 40: ...40 Installation Manual 1 4 Data Security ...
Page 76: ...76 Installation Manual 2 3 3 System Capacity ...
Page 108: ...108 Installation Manual 3 1 3 Using CTI Applications ...
Page 267: ...the priority Installation Manual 267 5 8 3 Setting LLDP Parameters ...
Page 312: ...312 Installation Manual 5 12 Automatic Configuration of Mailboxes ...
Page 318: ...318 Installation Manual 6 2 Methods of Stacking PBXs ...
Page 332: ...332 Installation Manual 7 1 6 Troubleshooting by Error Log ...