Manual programming is compulsory for the following parameters:
•
User Name
: Specifies the user name (SIP Account) provided by the SIP provider. (Max. 64 characters)
•
Authentication ID
: Specifies the authentication ID required for registration with the SIP server. (Max. 64
characters)
•
Authentication Password
: Specifies the authentication password used for registration with the SIP
provider. (Max. 32 characters)
Follow the steps below to programme these 3 parameters.
1.
Click an
Account
tab.
2.
In the
User Name
column, enter the user name provided
by the SIP provider.
3.
In the
Authentication ID
column, enter the
authentication ID required for registration with the SIP
server.
4.
In the
Authentication Password
column, the
authentication password used for registration with the
SIP provider.
5.
Click
OK
.
Adding Settings to Provider Profiles
Follow the steps below to add the settings to provider profiles.
1.
Click
Add Provider
.
A dialogue box will appear. Available virtual SIP gateway
port numbers are displayed in the list.
2.
Highlight the desired port numbers or click
Select All
to
select all the virtual SIP gateway port numbers to add
the settings to provider profiles.
3.
Click
Execute
.
Note
For more details about SIP gateway port settings, refer to the PC Programming Manual.
Installation Manual
239
5.7 Programming SIP Trunks
Summary of Contents for KX-NS1000
Page 40: ...40 Installation Manual 1 4 Data Security ...
Page 76: ...76 Installation Manual 2 3 3 System Capacity ...
Page 108: ...108 Installation Manual 3 1 3 Using CTI Applications ...
Page 267: ...the priority Installation Manual 267 5 8 3 Setting LLDP Parameters ...
Page 312: ...312 Installation Manual 5 12 Automatic Configuration of Mailboxes ...
Page 318: ...318 Installation Manual 6 2 Methods of Stacking PBXs ...
Page 332: ...332 Installation Manual 7 1 6 Troubleshooting by Error Log ...
Page 400: ...400 Installation Manual 8 6 26 WAN Port Mirroring ...
Page 414: ...414 Installation Manual 9 3 7 PCMPR Software File Version 004 1xxxx ...