I/O Allocation
3-20
Contact
allocation
Target
axis
Name
Description
WY
110
Y1100
All axes System stop
Contact for requesting the system stop. When it turns on, all axes will
stop at the deceleration time 0.
Y1101
-
-
-
Y1102
All axes Cam table
reading request
Turn ON this signal for reading cam tables. The cam table of a
specified cam pattern number will be read when this signal turns ON.
After the completion of the reading of cam tables, the cam table
reading done contact (X1102) turns ON.
Y1103
All axes Cam table
rewriting request
Turn ON this signal for reading cam tables. The cam table of a
specified cam pattern number will be rewritten when this signal turns
ON.
After the completion of the rewriting cam tables, the cam table
rewriting done contact (X1103) turns ON.
Y1104
-
-
-
Y1105
All axes Axis group setting
change request
This contact will turn ON after the axis group settings are changed.
Y1106
-
-
-
Y1107
All axes Recalculation
request
Turn on this signal when each positioning data (standard area) in the
positioning memory was changed. The positioning data after the
table number starting the recalculation specified in the positioning
memory can be restructured and will be executable by turning on this
signal. When restructuring of the positioning data completes, the
recalculation done contact (X1107) turns on.
Note) It is used only when the positioning data has been rewritten by
laddar programs.
Y1108
-Y110F
-
-
-
WY
111
Y111E
-Y111F
-
-
-
Summary of Contents for FP-XH M8N16PD
Page 1: ......
Page 23: ...1 System Structure ...
Page 39: ...2 Control Unit Specifications ...
Page 48: ...Control Unit Specifications 2 10 ...
Page 49: ...3 I O Allocation ...
Page 77: ...4 Installation ...
Page 89: ...5 Wiring of Power Supply and General purpose I O Parts ...
Page 104: ...Wiring of Power Supply and General purpose I O Parts 5 16 ...
Page 105: ...6 Wiring of Motion I O Parts ...
Page 116: ...Wiring of Motion I O Parts 6 12 ...
Page 117: ...7 Power On Off and Check Items ...
Page 124: ...Power On Off and Check Items 7 8 ...
Page 125: ...8 Steps Before Running ...
Page 142: ...Steps Before Running 8 18 ...
Page 143: ...9 Setting of Position Control Parameters ...
Page 159: ...10 Transfer to Unit and Commissioning ...
Page 181: ...11 Automatic Operation Position Control ...
Page 193: ...11 2 Interpolation Control 11 13 ...
Page 209: ...12 Automatic Operation Synchronous Control ...
Page 251: ...13 Manual Operation JOG Operation ...
Page 256: ...Manual Operation JOG Operation 13 6 ...
Page 257: ...14 Manual Operation Home Return ...
Page 264: ...Manual Operation Home Return 14 8 ...
Page 265: ...15 Pulse Input Function ...
Page 278: ...Pulse Input Function 15 14 ...
Page 279: ...16 Stop Function ...
Page 285: ...17 Auxiliary Function ...
Page 329: ...18 Instruction Reference ...
Page 357: ...19 Error Warning Annunciation Function ...
Page 386: ...Error Warning Annunciation Function 19 30 ...
Page 387: ...20 Troubleshooting ...
Page 402: ...Troubleshooting 20 16 ...
Page 403: ...21 Memory Master Memory Cassette ...
Page 418: ...Memory Master Memory Cassette 21 16 ...
Page 419: ...22 Security Functions ...
Page 430: ...Security Functions 22 12 ...
Page 431: ...23 General purpose Input High speed counter Function ...
Page 448: ...General purpose Input High speed counter Function 23 18 ...
Page 449: ...24 Other Functions ...
Page 452: ...Other Functions 24 4 ...
Page 453: ...25 Maintenance and Inspection ...
Page 457: ...26 Specifications ...
Page 552: ...Specifications 26 96 ...
Page 553: ...Record of changes Manual No Date Record of Changes WUME FPXHM8N16PD 01 Sep 2017 First Edition ...
Page 554: ......
Page 555: ......
Page 556: ......