I/O Allocation
3-18
Contact
allocation
Target
axis
Name
Description
WX
132
X1320
-X132F
-
-
-
WX
133
X1330
Axis 1
Slave axis clutch
operation
annunciation
The clutch will start operating when the slave axis clutch ON re-
request contact (Y1330 to Y1337) or clutch OFF request contact
(Y1340 to Y1347) turns ON.
The contact for the corresponding axis turns ON after the
completion of the operation of the clutch.
X1331
Axis 2
X1332
Axis 3
X1333
Axis 4
X1334
Axis 5
X1335
Axis 6
X1336
Axis 7
(virtual)
X1337
Axis 8
(virtual)
X1338
-X133F
-
-
-
WX
134
X1340
-X134F
-
-
-
WX
135
X1350
-X135F
-
-
-
WX
136
X1360
-X136F
-
-
-
WX
137
X1370
-X137F
-
-
-
WX
138
X1380
Axis 1
Positioning speed
change request
reception
annunciation
Starts the speed change operation when the positioning speed
change request contact (Y1380 to Y1387) turns ON. The contact
for the corresponding axis turns ON when he request is
accepted.
X1381
Axis 2
X1382
Axis 3
X1383
Axis 4
X1384
Axis 5
X1385
Axis 6
X1386
Axis 7
(virtual)
X1387
Axis 8
(virtual)
X1388
-X138F
-
-
-
(Note 1): When using the virtual axes, the I/O numbers allocated vary according to the number of virtual axes.
When selecting virtual 1st
axis
The I/O number of "Axis 8 (virtual)" in the above table is allocated to "virtual
1st axis".
When selecting virtual 1st
and 2nd axes
The I/O number of "Axis 7 (virtual)" in the above table is allocated to "virtual
1st axis".
The I/O number of "Axis 8 (virtual)" in the above table is allocated to "virtual
2nd axis".
Summary of Contents for FP-XH M8N16PD
Page 1: ......
Page 23: ...1 System Structure ...
Page 39: ...2 Control Unit Specifications ...
Page 48: ...Control Unit Specifications 2 10 ...
Page 49: ...3 I O Allocation ...
Page 77: ...4 Installation ...
Page 89: ...5 Wiring of Power Supply and General purpose I O Parts ...
Page 104: ...Wiring of Power Supply and General purpose I O Parts 5 16 ...
Page 105: ...6 Wiring of Motion I O Parts ...
Page 116: ...Wiring of Motion I O Parts 6 12 ...
Page 117: ...7 Power On Off and Check Items ...
Page 124: ...Power On Off and Check Items 7 8 ...
Page 125: ...8 Steps Before Running ...
Page 142: ...Steps Before Running 8 18 ...
Page 143: ...9 Setting of Position Control Parameters ...
Page 159: ...10 Transfer to Unit and Commissioning ...
Page 181: ...11 Automatic Operation Position Control ...
Page 193: ...11 2 Interpolation Control 11 13 ...
Page 209: ...12 Automatic Operation Synchronous Control ...
Page 251: ...13 Manual Operation JOG Operation ...
Page 256: ...Manual Operation JOG Operation 13 6 ...
Page 257: ...14 Manual Operation Home Return ...
Page 264: ...Manual Operation Home Return 14 8 ...
Page 265: ...15 Pulse Input Function ...
Page 278: ...Pulse Input Function 15 14 ...
Page 279: ...16 Stop Function ...
Page 285: ...17 Auxiliary Function ...
Page 329: ...18 Instruction Reference ...
Page 357: ...19 Error Warning Annunciation Function ...
Page 386: ...Error Warning Annunciation Function 19 30 ...
Page 387: ...20 Troubleshooting ...
Page 402: ...Troubleshooting 20 16 ...
Page 403: ...21 Memory Master Memory Cassette ...
Page 418: ...Memory Master Memory Cassette 21 16 ...
Page 419: ...22 Security Functions ...
Page 430: ...Security Functions 22 12 ...
Page 431: ...23 General purpose Input High speed counter Function ...
Page 448: ...General purpose Input High speed counter Function 23 18 ...
Page 449: ...24 Other Functions ...
Page 452: ...Other Functions 24 4 ...
Page 453: ...25 Maintenance and Inspection ...
Page 457: ...26 Specifications ...
Page 552: ...Specifications 26 96 ...
Page 553: ...Record of changes Manual No Date Record of Changes WUME FPXHM8N16PD 01 Sep 2017 First Edition ...
Page 554: ......
Page 555: ......
Page 556: ......