Automatic Operation (Position Control)
11-28
Operation diagram
f [pps]
10000
6000
20000
t [ms]
100
150
200
Positioning start contact Y1140
Operation done flag X1140
BUSY flag X1130
Operation of each contact
•
The BUSY flag (X1130), which indicates that the motor is running, will turn ON when the
positioning control starts, and it will turn OFF when the operation completes.
•
The operation done flag (X1140), which indicates the completion of operation, will turn ON
when the current operation is completed, and it will be held until the next positioning control,
JOG operation, home return, or pulser operation starts.
Sample program
X1100
Start enabled
condition
X1104
X1230
R10
R2
Specify axis no.
and table no.
R2
R10
X1130
Y1140
Positioning start
(
)
DF
(
)
DF
Specify repeat
count
F386 PSET
K1
K0
F0 MV
DT100
K3
Repeat
count
Specify repeat
count setting area
DT100
H108
K1
1 word
Axis 1 repeat
count setting
area
H0
F385 PTBLW
Common
area
R0
Servo ON
R1
Y1130
Servo OFF
(
)
DF
(
)
DF
Y1120
X1180 X1120
Tool
operation
Axis 1
error
Position
control start
Start enable
flag
Axis no. Table no.
Servo ON
Servo OFF
Axis 1 servo
OFF request
Axis 1 servo
ON request
Axis 1
connection
confirmation
Axis 1
servo lock
Link
establishment
annunciation
Position
control start
Start enable
flag
Axis 1
BUSY
Axis 1
positioning
start
Summary of Contents for FP-XH M8N16PD
Page 1: ......
Page 23: ...1 System Structure ...
Page 39: ...2 Control Unit Specifications ...
Page 48: ...Control Unit Specifications 2 10 ...
Page 49: ...3 I O Allocation ...
Page 77: ...4 Installation ...
Page 89: ...5 Wiring of Power Supply and General purpose I O Parts ...
Page 104: ...Wiring of Power Supply and General purpose I O Parts 5 16 ...
Page 105: ...6 Wiring of Motion I O Parts ...
Page 116: ...Wiring of Motion I O Parts 6 12 ...
Page 117: ...7 Power On Off and Check Items ...
Page 124: ...Power On Off and Check Items 7 8 ...
Page 125: ...8 Steps Before Running ...
Page 142: ...Steps Before Running 8 18 ...
Page 143: ...9 Setting of Position Control Parameters ...
Page 159: ...10 Transfer to Unit and Commissioning ...
Page 181: ...11 Automatic Operation Position Control ...
Page 193: ...11 2 Interpolation Control 11 13 ...
Page 209: ...12 Automatic Operation Synchronous Control ...
Page 251: ...13 Manual Operation JOG Operation ...
Page 256: ...Manual Operation JOG Operation 13 6 ...
Page 257: ...14 Manual Operation Home Return ...
Page 264: ...Manual Operation Home Return 14 8 ...
Page 265: ...15 Pulse Input Function ...
Page 278: ...Pulse Input Function 15 14 ...
Page 279: ...16 Stop Function ...
Page 285: ...17 Auxiliary Function ...
Page 329: ...18 Instruction Reference ...
Page 357: ...19 Error Warning Annunciation Function ...
Page 386: ...Error Warning Annunciation Function 19 30 ...
Page 387: ...20 Troubleshooting ...
Page 402: ...Troubleshooting 20 16 ...
Page 403: ...21 Memory Master Memory Cassette ...
Page 418: ...Memory Master Memory Cassette 21 16 ...
Page 419: ...22 Security Functions ...
Page 430: ...Security Functions 22 12 ...
Page 431: ...23 General purpose Input High speed counter Function ...
Page 448: ...General purpose Input High speed counter Function 23 18 ...
Page 449: ...24 Other Functions ...
Page 452: ...Other Functions 24 4 ...
Page 453: ...25 Maintenance and Inspection ...
Page 457: ...26 Specifications ...
Page 552: ...Specifications 26 96 ...
Page 553: ...Record of changes Manual No Date Record of Changes WUME FPXHM8N16PD 01 Sep 2017 First Edition ...
Page 554: ......
Page 555: ......
Page 556: ......