11.1 Basic Operations
11-3
Name Timing Charts
Actions and Purposes
Repe-
tition
Interpo-
lation
J-point
Control
No Speed Change
t[ms]
f[Hz]
J
E
①
Controlling via the speed point (JOG
Operation Point) is called "J-point
Control".
Perform control at the set speed
after startup.
Start the position control when the J-
point position control contact is in ON.
Change speed when the J-point
speed change flag is set
①
Position control contact of
Point J
②
Speed change flag of Point J
−
−
Speed Change
t[ms]
f[Hz]
J
E
①
②
Selection of the position control operation pattern
Select the position control operation pattern with the Configurator PM7.
•
Enter the mode in 1 line of the E-point control.
•
During continuous input of data tables with P point control, C point control and J point control,
executes combined input to make the final data table adopt E-point control.
KEY POINTS
•
When using P: passing point, C: continuance point, J: the next line of the
speed point is not selected and E: end point, detect the self-diagnostic error.
Setting the J-point control
•
Only select the "Increment" with the J-point control.
•
Set the changed target speed in the dialog box of the position control parameters for the
speed change with the J-point control.
Summary of Contents for FP-XH M8N16PD
Page 1: ......
Page 23: ...1 System Structure ...
Page 39: ...2 Control Unit Specifications ...
Page 48: ...Control Unit Specifications 2 10 ...
Page 49: ...3 I O Allocation ...
Page 77: ...4 Installation ...
Page 89: ...5 Wiring of Power Supply and General purpose I O Parts ...
Page 104: ...Wiring of Power Supply and General purpose I O Parts 5 16 ...
Page 105: ...6 Wiring of Motion I O Parts ...
Page 116: ...Wiring of Motion I O Parts 6 12 ...
Page 117: ...7 Power On Off and Check Items ...
Page 124: ...Power On Off and Check Items 7 8 ...
Page 125: ...8 Steps Before Running ...
Page 142: ...Steps Before Running 8 18 ...
Page 143: ...9 Setting of Position Control Parameters ...
Page 159: ...10 Transfer to Unit and Commissioning ...
Page 181: ...11 Automatic Operation Position Control ...
Page 193: ...11 2 Interpolation Control 11 13 ...
Page 209: ...12 Automatic Operation Synchronous Control ...
Page 251: ...13 Manual Operation JOG Operation ...
Page 256: ...Manual Operation JOG Operation 13 6 ...
Page 257: ...14 Manual Operation Home Return ...
Page 264: ...Manual Operation Home Return 14 8 ...
Page 265: ...15 Pulse Input Function ...
Page 278: ...Pulse Input Function 15 14 ...
Page 279: ...16 Stop Function ...
Page 285: ...17 Auxiliary Function ...
Page 329: ...18 Instruction Reference ...
Page 357: ...19 Error Warning Annunciation Function ...
Page 386: ...Error Warning Annunciation Function 19 30 ...
Page 387: ...20 Troubleshooting ...
Page 402: ...Troubleshooting 20 16 ...
Page 403: ...21 Memory Master Memory Cassette ...
Page 418: ...Memory Master Memory Cassette 21 16 ...
Page 419: ...22 Security Functions ...
Page 430: ...Security Functions 22 12 ...
Page 431: ...23 General purpose Input High speed counter Function ...
Page 448: ...General purpose Input High speed counter Function 23 18 ...
Page 449: ...24 Other Functions ...
Page 452: ...Other Functions 24 4 ...
Page 453: ...25 Maintenance and Inspection ...
Page 457: ...26 Specifications ...
Page 552: ...Specifications 26 96 ...
Page 553: ...Record of changes Manual No Date Record of Changes WUME FPXHM8N16PD 01 Sep 2017 First Edition ...
Page 554: ......
Page 555: ......
Page 556: ......