R
W
DT90053
Real-time clock monitoring
(hour and minute)
Saves the hour and minute data of the real-time
clock.
You can only read, can not write.
High byte
Low byte
Hour dataH00
~
H23 Minute dataH00
~
H59
○
×
DT90054
Real-time clock
(minute and second)
Saves the month, day, hour, minute, second, day and
week data of the real-time clock. The built-in real time
clock is applicable until 2099, also applicable for leap
years.
The real-time clock can be set (time adjustment) by
using the programming tool or transfer instruction
(F0) program to write in values.
High byte
Low byte
DT90054
DT90055
DT90056
DT90057
Minute data
(H00
~
H59)
Day data
(H01
~
H31)
Year data
(H00
~
H99)
Second data
(H00
~
H59)
Hour data
(H00
~
H23)
Month data
(H01
~
H12)
Week data
(H00
~
H06)
ー
The week data is not automatically set. Allocate any
value within the range of H0 - 6.
○
○
DT90055
Real-time clock
(day and hour)
DT90056
Real-time clock
(year and month)
DT90057
Real-time clock
(week)
DT90058
Real-time clock time setting
and 30 seconds correction
register
Time adjustment for real-time clock.
●Use the program to
adjust the time
If the highest bit of the DT90058 MSB is set to 1, it
turns to the time written into the DT90054 - DT90057
by the instruction F0. After executing time
adjustment, the DT90058 is cleared. (You can not
execute instructions other than F0.)
<Example> When X0 is ON, adjust the time to 5 days
12 hours 0 minute 0 second.
F0 MV, H 0, DT90054
Set 0 minutes 0 seconds
Set 5 days 12 hours
Time alignment
F0 MV, H 512, DT90055
F0 MV, H8000, DT90058
DF
X0
●Correct the error within 30 seconds
If the lowest bit of the DT90058 MSB is set to 1, it will
increase or decrease and turn to 0 second.
After performing the correction, the DT90058 is
cleared.
<Example> When X0 is ON, correct it to 0 second.
F0 MV, H 1, DT90058
Corrected to 0 second
DF
X0
Decrease when the execution time is 0-29 seconds,
increase when it is 30-59 seconds. In the above
example, if the time is 5 minutes and 29 seconds, it
turns to 5 minutes 0 seconds. If the time is 5 minutes
and 35 seconds, it turns to 6 minutes 0 seconds.
○
○
(Note 1): If you use the programming tool to rewrite the value of DT90054 - DT90057, the time is adjusted to the time
written at the time of rewriting. Therefore, do not execute DT90058 writing.
Summary of Contents for FP-XH M8N16PD
Page 1: ......
Page 23: ...1 System Structure ...
Page 39: ...2 Control Unit Specifications ...
Page 48: ...Control Unit Specifications 2 10 ...
Page 49: ...3 I O Allocation ...
Page 77: ...4 Installation ...
Page 89: ...5 Wiring of Power Supply and General purpose I O Parts ...
Page 104: ...Wiring of Power Supply and General purpose I O Parts 5 16 ...
Page 105: ...6 Wiring of Motion I O Parts ...
Page 116: ...Wiring of Motion I O Parts 6 12 ...
Page 117: ...7 Power On Off and Check Items ...
Page 124: ...Power On Off and Check Items 7 8 ...
Page 125: ...8 Steps Before Running ...
Page 142: ...Steps Before Running 8 18 ...
Page 143: ...9 Setting of Position Control Parameters ...
Page 159: ...10 Transfer to Unit and Commissioning ...
Page 181: ...11 Automatic Operation Position Control ...
Page 193: ...11 2 Interpolation Control 11 13 ...
Page 209: ...12 Automatic Operation Synchronous Control ...
Page 251: ...13 Manual Operation JOG Operation ...
Page 256: ...Manual Operation JOG Operation 13 6 ...
Page 257: ...14 Manual Operation Home Return ...
Page 264: ...Manual Operation Home Return 14 8 ...
Page 265: ...15 Pulse Input Function ...
Page 278: ...Pulse Input Function 15 14 ...
Page 279: ...16 Stop Function ...
Page 285: ...17 Auxiliary Function ...
Page 329: ...18 Instruction Reference ...
Page 357: ...19 Error Warning Annunciation Function ...
Page 386: ...Error Warning Annunciation Function 19 30 ...
Page 387: ...20 Troubleshooting ...
Page 402: ...Troubleshooting 20 16 ...
Page 403: ...21 Memory Master Memory Cassette ...
Page 418: ...Memory Master Memory Cassette 21 16 ...
Page 419: ...22 Security Functions ...
Page 430: ...Security Functions 22 12 ...
Page 431: ...23 General purpose Input High speed counter Function ...
Page 448: ...General purpose Input High speed counter Function 23 18 ...
Page 449: ...24 Other Functions ...
Page 452: ...Other Functions 24 4 ...
Page 453: ...25 Maintenance and Inspection ...
Page 457: ...26 Specifications ...
Page 552: ...Specifications 26 96 ...
Page 553: ...Record of changes Manual No Date Record of Changes WUME FPXHM8N16PD 01 Sep 2017 First Edition ...
Page 554: ......
Page 555: ......
Page 556: ......