12/1/99
3-10
Logging Data
TIME INCREMENT
Prompt
Regardless of which of the various options were selected during the
previous programming steps, all of the paths converge at this point.
Note:
The available options at this prompt are: 5sec, 10sec, 30sec,
1min, 3min, 6min, 12min, 30min and 60 min.
The time increment is the frequency at which the Model GF868 takes
and records data measurements. If any reading takes longer than the
programmed time increment, the log is filled in with the next
consecutive reading. For example, assume that a velocity value of 3
ft/sec is recorded at 12:00:00 in a log with a time increment of five
seconds. If the next reading is 8 ft/sec and it takes the meter 12
seconds to read this value, then both of the missed readings (12:00:05
and 12:00:10) will be filled in with the 8 ft/sec value.
Although each log is restricted to only three logged parameters, it is
still possible to log more than three parameters. Simply re-enter the
STD
sub-menu as many times as necessary to set up additional logs.
Select the other desired parameters, and run these logs simultaneously
with the first log.
NAME,MESSAGE,etc.
É
Use the [
←]
, [
→]
and
[F1]-[F4]
keys to select the desired time
increment.
previous prompt appears here
previous selection appears here
TIME INCREMENT
previous value appears here
5sec
10sec
30sec
1min
LOG Start
Use [
↑]
and [
↓]
to review the
previous menu prompts, or press
[F1]-[F4]
to select one of the sub-
menus. To return to the data
screen and begin logging data,
press the
[ENT]
key.
LOGGING
Standard Log
STD
MEM
STOP
ERROR
Summary of Contents for GF868
Page 1: ...Model GF868 Programming Manual Two Channel...
Page 6: ...Chapter 1...
Page 71: ...Chapter 2...
Page 92: ...Chapter 3...
Page 113: ...Chapter 4...
Page 131: ...Chapter 5...
Page 138: ...12 1 99 5 6 Clearing Data...
Page 139: ...Chapter 6...
Page 150: ...Appendix A...
Page 159: ...Appendix B...
Page 160: ...Data Records Option Cards Installed B 1 Initial Setup Data B 2...