Six-Rack Cabling
Leaf Switch
Connection
Cable Length
R5-U32-P9B to R1-U1-P6A
R5 U32 to Rack 2
R5-U32-P10A to R2-U1-P7A
R5-U32-P10B to R2-U1-P8A
10 meters
R5 U32 to Rack 3
R5-U32-P11A to R3-U1-P9A
5 meters
R5 U32 to Rack 4
R5-U32-P11B to R4-U1-P10A
5 meters
R5 U26 within Rack 5
R5-U26-P8A to R5-U1-P3B
R5-U26-P8B to R5-U1-P4B
3 meters
R5 U26 to Rack 1
R5-U26-P9A to R1-U1-P5B
R5-U26-P9B to R1-U1-P6B
10 meters
R5 U26 to Rack 2
R5-U26-P10A to R2-U1-P7B
R5-U26-P10B to R2-U1-P8B
10 meters
R5 U26 to Rack 3
R5-U26-P11A to R3-U1-P9B
5 meters
R5 U26 to Rack 4
R5-U26-P11B to R4-U1-P10B
5 meters
Six-Rack Cabling
The following table shows the cable connections for the first spine switch (R1-U1) when
cabling six full racks together.
TABLE 36
Leaf Switch Connections for the First Rack in a Six-Rack System
Leaf Switch
Connection
Cable Length
R1 U32 within Rack 1
R1-U32-P8A to R1-U1-P3A
R1-U32-P8B to R1-U1-P4A
3 meters
R1 U32 to Rack 2
R1-U32-P9A to R2-U1-P5A
R1-U32-P9B to R2-U1-P6A
5 meters
R1 U32 to Rack 3
R1-U32-P10A to R3-U1-P7A
5 meters
R1 U32 to Rack 4
R1-U32-P10B to R4-U1-P8A
10 meters
R1 U32 to Rack 5
R1-U32-P11A to R5-U1-P9A
10 meters
R1 U32 to Rack 6
R1-U32-P11B to R6-U1-P10A
10 meters
R1 U26 within Rack 1
R1-U26-P8A to R1-U1-P3B
R1-U26-P8B to R1-U1-P4B
3 meters
R1 U26 to Rack 2
R1-U26-P9A to R2-U1-P5B
R1-U26-P9B to R2-U1-P6B
5 meters
Connecting Multiple Oracle SuperCluster T5-8 Systems
273
Summary of Contents for SuperCluster T5-8
Page 1: ...Oracle SuperCluster T5 8 Owner s Guide Part No E40167 17 May 2016 ...
Page 2: ......
Page 11: ...Contents Index 353 11 ...
Page 12: ...12 Oracle SuperCluster T5 8 Owner s Guide May 2016 ...
Page 14: ...14 Oracle SuperCluster T5 8 Owner s Guide May 2016 ...
Page 116: ...116 Oracle SuperCluster T5 8 Owner s Guide May 2016 ...
Page 204: ...204 Oracle SuperCluster T5 8 Owner s Guide May 2016 ...
Page 228: ...228 Oracle SuperCluster T5 8 Owner s Guide May 2016 ...
Page 244: ...244 Oracle SuperCluster T5 8 Owner s Guide May 2016 ...