![background image](http://html1.mh-extra.com/html/omron/viper-650/viper-650_user-manual_743998136.webp)
136
Viper 650 and 850 Robot with EtherCAT
21861-000 Rev A
Figure 10-5. Viper 850 J6 Cleanroom Cover
Any user tooling at the flange must allow for clearance. See the following figure.
40.0 -
0.000
0.039
3x 5.5
59
3.7
0.43
3.0
A
B
C
Figure 10-6. J6 Cleanroom Cover Dimensions (units in mm)
Key
Meaning
Key Meaning
A
M3 Bolt Head
C
Chamfer
B
Bolt Circle (BC)
NOTE:
Clearance must be made between the J6 Cleanroom Cover and user tool-
ing.
10.4 Cleanroom Technical Specifications
Table 10-4. Cleanroom Robot Specifications
Viper 650/850
Clean Class for Cleanroom Robot
Class 10
Recommended vacuum flow rate
130 liters/minute (4.6 SCFM)
User air lines
6 systems (
Ø
4x6), 3 solenoid valves (2-position,
double solenoid) contained.