No.
Parameter Name
Default Setting
E1-03
V/f Pattern Selection
0FH
L2-01
Momentary Power Loss Operation Selection
1: Enabled
L3-04
Stall Prevention Selection during Deceleration
1: Enabled
Table 4.14 Compressor: User Parameters (A2-01 to A2-16):
No.
Parameter Name
No.
Parameter Name
b1-01
Frequency Reference Selection
E1-03
V/f Pattern Selection
b1-02
Run Command Selection
E1-07
Mid Output Frequency
b1-04
Reverse Operation Selection
E1-08
Mid Output Frequency Voltage
C1-01
Acceleration Time 1
E2-01
Motor Rated Current
C1-02
Deceleration Time 1
−
−
u
Setting 6: Hoist Application
Note: 1.
Read the instructions listed on page
84
when using Hoist Application Preset
2.
Perform Auto-Tuning after selecting the Hoist Application Preset.
Table 4.15 Hoist: Parameters and Settings
No.
Parameter Name
Default Setting
A1-02
Control Method Selection
2: Open Loop Vector Control
b1-01
Frequency Reference Selection
0: Operator
b6-01
Dwell Reference at Start
3.0 Hz
b6-02
Dwell Time at Start
0.3 s
C1-01
Acceleration Time 1
3.0 s
C1-02
Deceleration Time 1
3.0 s
C6-01
Duty Rating
0: Heavy Duty
C6-02
Carrier Frequency Selection
2: 5 kHz
d1-01
Frequency Reference 1
6.0 Hz
d1-02
Frequency Reference 2
30.0 Hz
d1-03
Frequency Reference 3
50.0 Hz
E1-03
V/f Pattern Selection
0FH
H2-02
Terminals P1 Function Selection
37: During Frequency Output
H2-03
Terminals P2 Function Selection
5: Frequency Detection 2
L2-03
Momentary Power Loss Minimum Baseblock Time
0.3 s
L3-04
Momentary Power Loss Voltage Recovery Ramp Time 0: Disabled
L4-01
Speed Agreement Detection Level
2.0 Hz
L4-02
Speed Agreement Detection Width
0.0 Hz
L6-01
Torque Detection Selection 1
8: UL3 at RUN - Fault
L6-02
Torque Detection Level 1
5%
L6-03
Torque Detection Time 1
0.5 s
L8-05
Input Phase Loss Protection Selection
1: Enabled
<1>
L8-07
Output Phase Loss Protection
1: Enabled
L8-38
Carrier Frequency Reduction
1: Enabled below 6 Hz
L8-41
Current Alarm Selection
1: Enabled (alarm is output)
<1> Disable L8-05 for single-phase models.
Table 4.16 Hoist: User Parameters (A2-01 to A2-16):
No.
Parameter Name
No.
Parameter Name
A1-02
Control Method Selection
d1-02
Frequency Reference 2
b1-01
Frequency Reference Selection
d1-03
Frequency Reference 3
b6-01
Dwell Reference at Start
E1-08
Mid Output Frequency Voltage
b6-02
Dwell Time at Start
H2-01
Terminals MA, MB, and MC Function Selection
C1-01
Acceleration Time 1
L1-01
Motor Overload Protection Selection
C1-02
Deceleration Time 1
L4-01
Speed Agreement Detection Level
C6-02
Carrier Frequency Selection
L6-02
Torque Detection Level 1
d1-01
Frequency Reference 1
L6-03
Torque Detection Time 1
u
Notes on Controlling the Brake when Using the Hoist Application Preset
Preventing Inadvertent Brake Release by Disabling Frequency Detection During a Baseblock Condition
4.6 Application Selection
84