u
A2: User Parameters
n
A2-01 to A2-32: User Parameters
The user can select 32 parameters and assign them to A2-01 through A2-32. This saves time later scrolling through the
parameter menu. The list of User Parameters can also track the most recently edited settings and save those parameters to
this list.
No.
Parameter Name
Setting Range
Default
A2-01 to A2-32
User Parameters 1 to 32
b1-01 to o2-08
Depending on
A1-06
Saving User Parameters
To save specific parameters to A2-01 to A2-32, first set the access level to allow access to all parameters (A1-02 = 2).
Next assign the parameter number to the User Parameters list by entering it into one of the A2-
parameters. By then
setting A1-01 to “1”, the access level can be restricted so that users can only set and reference the specific parameters
saved as User Parameters.
n
A2-33: User Parameter Automatic Selection
A2-33 determines whether or not parameters that have been edited are saved to the User Parameters (A2-17 to A2-32) for
quick, easy access.
No.
Parameter Name
Setting Range
Default
A2-33
User Parameter Automatic Selection
0 or 1
Depending on
A1-06
Setting 0: Do not save list of recently viewed parameters.
To manually select the parameters listed in the User Parameter group, set A2-33 to “0”.
Setting 1: Save history of recently viewed parameters.
By setting A2-33 to 1, all parameters that were recently edited will be automatically saved to A2-17 through A2-32. A
total of 16 parameters are saved in order with the most recently edited parameter set to A2-17. User parameters can be
accessed using the Setup mode of the digital operator.
5.1 A: Initialization
SIEP C710606 20 OYMC AC Drive - V1000 User Manual
101
5
Parameter Details
7/16/2008-13:23