![background image](http://html.mh-extra.com/html/omron/v1000/v1000_user-manual_741325349.webp)
B.6 Parameters that Change with the Motor Code Selection
The following tables show parameters and default settings that change with the motor code selection E5-01 when Open
Loop Vector for PM motors is used.
u
Yaskawa SMRA Series SPM Motor
Table B.8 1800 rpm Type Yaskawa SMRA Series SPM Motor Settings
Par.
Description
Unit
Default Settings
E5-01
Motor Code
−
0002
0003
0005
0006
0008
Voltage class
−
200 Vac
200 Vac
200 Vac
200 Vac
200 Vac
Rated power
−
0.4 kW
0.75 kW
1.5 kW
2.2 kW
3.7 kW
Rated speed
r/min
1800
1800
1800
1800
1800
E5-02
Motor rated power
kW
0.4
0.75
1.5
2.2
3.7
E5-03
Motor rated current
A
2.1
4.0
6.9
10.8
17.4
E5-04
Motor pole number
–
8
8
8
8
8
E5-05
Motor winding resistance
W
2.47
1.02
0.679
0.291
0.169
E5-06
d-axis inductance
mH
12.7
4.8
3.9
3.6
2.5
E5-07
q-axis inductance
mH
12.7
4.8
3.9
3.6
2.5
E5-09
Induction voltage constant 1
mVs/rad
0
0
0
0
0
E5-24
Induction voltage constant 2
mV/(r/min)
62.0
64.1
73.4
69.6
72.2
E1-04
Maximum output frequency
Hz
120
120
120
120
120
E1-05
Maximum output voltage
V
200.0
200.0
200.0
200.0
200.0
E1-06
Base voltage
Hz
120
120
120
120
120
E1-09
Minimum output frequency
Hz
6
6
6
6
6
L3-24
Motor acceleration time
s
0.064
0.066
0.049
0.051
0.044
n8-49
Pull-in current
%
0
0
0
0
0
Table B.9 3600 rpm Type Yaskawa SMRA Series SPM Motor Settings
Par.
Description
Unit
Default Settings
E5-01
Motor Code
−
0103
0105
0106
0108
Voltage class
−
200 Vac
200 Vac
200 Vac
200 Vac
Rated power
−
0.75 kW
1.5 kW
2.2 kW
3.7 kW
Rated speed
r/min
3600
3600
3600
3600
E5-02
Motor rated power
kW
0.75
1.5
2.2
3.7
E5-03
Motor rated current
A
4.1
8.0
10.5
16.5
E5-04
Motor pole number
–
8
8
8
8
E5-05
Motor winding resistance
W
0.538
0.20
0.15
0.097
E5-06
d-axis inductance
mH
3.2
1.3
1.1
1.1
E5-07
q-axis inductance
mH
3.2
1.3
1.1
1.1
E5-09
Induction voltage constant 1
mVs/rad
0
0
0
0
E5-24
Induction voltage constant 2
mV/(r/min)
32.4
32.7
36.7
39.7
E1-04
Maximum output frequency
Hz
240
240
240
240
E1-05
Maximum output voltage
V
200.0
200.0
200.0
200.0
E1-06
Base voltage
Hz
240
240
240
240
E1-09
Minimum output frequency
Hz
12
12
12
12
L3-24
Motor acceleration time
s
0.064
0.066
0.049
0.051
n8-49
Pull-in current
%
0
0
0
0
B.6 Parameters that Change with the Motor Code Selection
348
SIEP C710606 20 OYMC AC Drive - V1000 User Manual
7/16/2008-13:23