No.
Name
Description
Analog Output
Level
Unit
Control
Mode
Addr.
Hex
V/f O
LV
P
M
U6: Control Monitor
Use U6 parameters to display drive control information.
U6-01
Motor Secondary Current
(Iq)
Displays the value of the motor secondary current (Iq).
10 V: 100%
0.1% A A A
51
U6-02
Motor Excitation Current
(ld)
Displays the value calculated for the motor excitation
current (Id).
10 V: 100%
0.1% − A A
52
U6-03 ASR Input
Displays the ASR input value if V/f Control with Simple
PG Feedback is enabled.
10 V: 100%
(max. freq.)
0.1% A − −
54
U6-04
ASR Output
Displays the ASR output value if V/f Control with Simple
PG Feedback is enabled.
10 V: 100%
(max. freq.)
0.1% A − −
55
U6-05
Output voltage reference
(Vq)
Output voltage reference (Vq). (q-axis)
10 V: 200 V
(400 V)
0.1
Vac
− A A
59
U6-06
Output Voltage Reference
(Vd)
Output voltage reference (Vd). (d-axis)
10 V: 200 V
(400 V)
0.1
Vac
− A A
5A
U6-07
q-axis ACR Output
Displays the current control (ACR) output of for the motor
secondary current (Iq).
10 V: 100%
0.1% − A −
5F
U6-08
d-Axis ACR Output
Displays the current control (ACR) output of for the motor
excitation current (Id).
10 V: 100%
0.1% − A −
60
U6-20
Frequency Reference Bias
(Up/Down 2)
Displays the bias value used to adjust the frequency
reference.
10 V: max.
frequency
0.1% A A A
7D4
U6-21
Offset Frequency
Displays the frequency added to the main frequency
reference.
10 V: max.
frequency
0.1% A A A
7D5
U8: Custom Monitors for FBDs
U8 parameters are reserved for FBDs
U8-01
–
Reserved for FBDs, Monitor 1.
–
0.01
%
Α A Α
1950
U8-02
–
Reserved for FBDs, Monitor 2.
–
0.01
%
A A A
1951
U8-03
–
Reserved for FBDs, Monitor 3.
–
0.01
%
A A A
1952
U8-04
–
Reserved for FBDs, Monitor 4.
–
0.01
%
A A A
1953
U8-05
–
Reserved for FBDs, Monitor 5.
–
0.01
%
A A A
1954
U8-06
–
Reserved for FBDs, Monitor 6.
–
0.01
%
A A A
1955
U8-07
–
Reserved for FBDs, Monitor 7.
–
0.01
%
A A A
1956
U8-08
–
Reserved for FBDs, Monitor 8.
–
0.01
%
A A A
1957
U8-09
–
Reserved for FBDs, Monitor 9.
–
0.01
%
A A A
1958
U8-10
–
Reserved for FBDs, Monitor 10.
–
0.01
%
A A A
1959
<27> Setting units for this parameter are determined by o2-04, Drive Model Selection. Less than 11 kW: 2 decimal points, 11 kW and above: 1
decimal point.
<59> Available in drive software 1011 and later.
<62> Valid from drive software version 1011. Max value is 65536 in older software.
B.2 Parameter Table
SIEP C710606 20 OYMC AC Drive - V1000 User Manual
337
B
Parameter List