B.4 V/f Pattern Default Values
The tables below show the V/f pattern settings default values depending on the control mode (A1-02) and the V/f pattern
selection (E1-03 in V/f Control).
Table B.3 E1-03 V/f Pattern Settings for Drive Capacity: VZAB0P1 to VZAB1P5;
VZA20P1 to VZA21P5; VZA40P2 to VZA41P5
No.
Unit
V/f Control
OLV
E1-03
−
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
E1-04
Hz
50.0
60.0
60.0
72.0
50.0
50.0
60.0
60.0
50.0
50.0
60.0
60.0
90.0
120
180
50.0
50.0
E1-05
<24>
V
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
E1-06
Hz
50.0
60.0
50.0
60.0
50.0
50.0
60.0
60.0
50.0
50.0
60.0
60.0
60.0
60.0
60.0
50.0
50.0
E1-07
Hz
2.5
3.0
3.0
3.0
25.0
25.0
30.0
30.0
2.5
2.5
3.0
3.0
3.0
3.0
3.0
2.5
3.0
E1-08
<24>
V
16.0
16.0
16.0
16.0
35.0
50.0
35.0
50.0
19.0
24.0
19.0
24.0
16.0
16.0
16.0
16.0
14.4
E1-09
Hz
1.3
1.5
1.5
1.5
1.3
1.3
1.5
1.5
1.3
1.3
1.5
1.5
1.5
1.5
1.5
1.3
0.5
E1-10
<24>
V
12.0
12.0
12.0
12.0
8.0
9.0
8.0
9.0
12.0
13.0
12.0
15.0
12.0
12.0
12.0
12.0
3.0
<24> Values shown here are for 200 V class drives. Double the value when using a 400 V class drive.
Table B.4 E1-03 V/f Pattern Settings for Drive Capacity: VZAB2P2 to VZAB4P0;
VZA22P2 to VZA2015; VZA42P2 to VZA4015
No.
Unit
V/f Control
OLV
E1-03
−
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
E1-04
Hz
50.0
60.0
60.0
72.0
50.0
50.0
60.0
60.0
50.0
50.0
60.0
60.0
90.0
120
180
50.0
50.0
E1-05
<24>
V
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
E1-06
Hz
50.0
60.0
50.0
60.0
50.0
50.0
60.0
60.0
50.0
50.0
60.0
60.0
60.0
60.0
60.0
50.0
50.0
E1-07
Hz
2.5
3.0
3.0
3.0
25.0
25.0
30.0
30.0
2.5
2.5
3.0
3.0
3.0
3.0
3.0
2.5
3.0
E1-08
<24>
V
14.0
14.0
14.0
14.0
35.0
50.0
35.0
50.0
18.0
23.0
18.0
23.0
14.0
14.0
14.0
14.0
13.2
E1-09
Hz
1.3
1.5
1.5
1.5
1.3
1.3
1.5
1.5
1.3
1.3
1.5
1.5
1.5
1.5
1.5
1.3
0.5
E1-10
<24>
V
7.0
7.0
7.0
7.0
6.0
7.0
6.0
7.0
9.0
11.0
9.0
13.0
7.0
7.0
7.0
7.0
2.4
<24> Values shown here are for 200 V class drives. Double the value when using a 400 V class drive.