FINS commands
Section 3-4
68
3-4-3
Parameter Area Read (0201)
The FINS Parameter Area Read command reads the memory-mapping
configuration that is written with the FINS Parameter Area Write command
(see section 3-4-4).
The Parameter Area Read command has this format:
/i
The parameters can have the following values:
/i
The CJ1W-MCH72 responds with these codes:
/i
If the response code is 0000, the CJ1W-MCH72 responds with the data
configured previously:
/i
Refer to section 3-4-4 for more information on the fields
plc_area
,
plc_start
,
tj_area
,
tj_start
and
total_items
.
3-4-4
Parameter Area Write (0202)
The FINS Parameter Area Write command sets the memory-mapping
configuration. It has this format:
/i
The parameters can have the following values:
/i
02
01
..
..
00
00
00
08
command_code
area_code
start_address
byte_count
Parameter
Values (hex)
command_code
02 01
area_code
•
0100..0107 for PLC output area (8 areas available)
•
8100..8107 for PLC input area (8 areas available)
start_address
0000
byte_count
0008
Condition
Response code
(hex)
Description
All elements valid
0000
OK
area_code
invalid
1101
No area type
start_address
invalid
1103
Address range designation error
byte_count
invalid
1104
Address out of range
area_code
not configured
2003
The registered table does not
exist
02
01
00
00
..
..
00
00 00 08
..
.. ..
..
.. .. .. ..
command_
code
response_
code
area_
code
start_
address
byte_
count
plc_
area
plc_
start
tj_
area
tj_
start
total_
items
02
02
00
00
..
..
00
00 00 08
..
.. ..
..
.. .. .. ..
command_
code
response_
code
area_
code
start_
address
byte_
count
plc_
area
plc_
start
tj_
area
tj_
start
total_
items
Parameter
Values (hex)
command_code
02 02