FINS commands
Section 3-4
67
3-4-2
Write (0102)
The FINS Write command has these formats:
• If
var_type
is 82 or B0:
/i
• If
var_type
is C2 or F0:
/i
• If
var_type
is 30:
/i
The parameters can have the following values:
/i
The CJ1W-MCH72 responds with these codes:
/i
01
02
..
..
..
00
..
..
..
..
.. ..
command_code
var_
type
start_
address
fixed
total_words
word 1
..
01
02
..
..
..
00
..
..
.. .. .. ..
..
command_code var_type
start_
address
fixed
total_ dwords dword 1
..
01
02
30
..
..
00
..
..
..
..
..
command_code
var_
type
start_
address
bit_
num
total_bits
bit
..
Parameter
Values
command_code
01 02
var_type
•
82 (Table memory in 16-bit integer format)
•
C2 (Table memory in 32-bit IEEE floating-point format)
•
B0 (VR memory in 16-bit integer format)
•
F0 (VR memory in 32-bit IEEE floating-point format)
•
30 (VR memory in bit format)
start_address
0
≤
start_address
≤
memory size
−
1
≤
FFFF
total_words
1
≤
total_words
≤
memory size -
start_address
+ 1
total_dwords
1
≤
total_dwords
≤
memory size -
start_address
+ 1
total_bits
1
bit
00 or 01
Condition
Response code
(hex)
Description
All elements valid
0000
OK
var_type
invalid
1101
No area type
start_address
invalid
1103
Address range designation error
bit_number
invalid
1103
Address range designation error
Number of elements invalid
(totals)
1104
Address out of range