All BASIC commands
Section 4-2
199
/i
/i
/i
Arguments
•
distance
The incremental distance in user units to move the BASE axis, as a
result of the measured
link_distance
movement on the link axis.
•
link_distance
The positive incremental distance in user units that is required to be
measured on the link axis to result in the distance motion on the
BASE axis.
•
link_acceleration
The positive incremental distance in user units on the link axis over
which the base axis will accelerate.
•
link_deceleration
The positive incremental distance in user units on the link axis over
which the base axis will decelerate.
Note: If the sum of parameter 3 and parameter 4 is greater than
parameter 2, they are both reduced in proportion until their sum
equals parameter 2.
•
link axis
The axis to link to.
•
link_option
See the table below.
link_option
Description
1
Link starts when registration event occurs on link axis.
2
Link starts at an absolute position on link axis (see
link_position
).
4
MOVELINK
repeats automatically and bidirectionally. This option is
cancelled by setting bit 1 of
REP_OPTION
parameter (that is,
REP_OPTION = REP_OPTION OR 2
).
5
Combination of options 1 and 4.
6
Combination of options 2 and 4.
•
link_position
The absolute position where
MOVELINK
will start when
link_option
is set to 2
Note: The command uses the BASE and AXIS, and unit conversion fac-
tors in a similar way to other MOVE commands.
Note: The “link” axis may move in either direction to drive the output
motion. The link distances specified are always positive.