40
Connecting H-PCF Cable Optical Ring System Cables
Section 2-2
• Do not pull on the Optical Fiber Cable.
The maximum tension that can be applied to the cord is 10 kg (about 22
lbs) and the maximum tension that can be applied to the cable is 50 kg
(about 110 lbs).
• Do not bend the cable paste its natural bending radius. The minimum
radius for bends is 10 cm.
• To prevent the Optical Fiber Cable from being pulled too forcefully,
always use the cable mounting bracket and provide space behind the
Board as shown in the following diagram. Do not exceed the maximum
tension for the cord and cable:
Cord:
0 kg (Do not apply any tension.)
Cable: 5 kg (about 11 lbs)
• Do not place objects on top of the Optical Fiber Cable. The maximum
pressure that can be placed on the cord and cable is as follows:
Cord:
30 kg/10 cm
Cable: 50 kg/10 cm
• Inspect the connector before installing it.
• When connecting or disconnecting the Optical Fiber Cable, be sure to
hold the connector firmly. (Do not pull on the cable itself.)
Cord
Cable
R
140 mm
Rear side of
the computer
Cord
Cable