32
Connecting Wired Systems
Section 2-1
Note
(a) Turn OFF the power supply to the computer before connecting
the communications cable or connecting/disconnecting a con-
nector.
(b) Use the connector attached to a Controller Link Support Board.
4. Strip the insulation far enough to attach the crimp terminals and twist the
wire strands tight.
5. Apply electrical tape or heat-shrink tubing to the end of the cable cover that
was peeled in step 1
6. Attach the crimp terminals to the shield wire and signal wires. Apply elec-
trical tape or heat-shrink tubing to the connections.
Note
We recommend the Phoenix AI-series crimp terminals shown in the
following diagram. The Phoenix Company’s ZA3 crimping tool can
be used to attach these terminals.
7. Carefully insert the signal line and shield line into each hole of the connec-
tor. Insert as marked on the connector. The following example shows con-
nection to a Board in the middle of the Network.
Wire created by
twisting the shield
Co
v
er with a
heat-shrink tubing
Lea
v
e enough exposed
wire to attach the terminal.
Apply
v
inyl tape or
a heat-shrink tubing.
Crimp terminal
Cable
Summary of Contents for SYSMAC 3G8F7-CLK12-EV1
Page 2: ......
Page 4: ...iv ...
Page 20: ...xx Conformance to EC Directives 6 ...
Page 48: ...28 Applications Precautions Section 1 4 Example CX Programmer Response Timeout Setting ...
Page 68: ...48 Backup Power Supply Wiring Optical Ring Systems Only Section 2 4 ...
Page 74: ...54 Using the C Library Section 3 2 ...
Page 110: ...90 Changing the Data Link Tables with Active Data Links Section 5 5 ...
Page 187: ......