160
Standard Models
Appendix A
Note
Special training is required to assemble Optical Fiber Cables and con-
nectors with epoxy adhesive. Contact your OMRON dealer for details
on other optical fiber cords and cables.
GI Optical Fiber Cables for Optical Ring Networks
Use graded index (GI) optical fiber cables with the following optical characteristics.
50/125
μ
m AGF
Lf: Fiber length in km, Ta: Ambient temperature,
λ
: Center wavelength of measurement light source
62.5/125
μ
m AGF
Lf: Fiber length in km, Ta: Ambient temperature,
λ
: Center wavelength of measurement light source
Connectors for GI Cable for Optical Ring Networks
Use ST connectors.
Optical Fiber Cable
Connectors:
CF-2001H
CF-2501H
2 m
S3200-CN201-20-25
5 m
S3200-CN501-20-25
10 m
S3200-CN102-20-25
15 m
S3200-CN152-20-25
20 m
S3200-CN202-20-25
Over
20 m
S3200-CN-20-25
(Specify length (m) when ordering.)
Optical Fiber Cable
Connectors:
CF-2501H
CF-2501H
2 m
S3200-CN201-25-25
5 m
S3200-CN501-25-25
10 m
S3200-CN102-25-25
15 m
S3200-CN152-25-25
20 m
S3200-CN202-25-25
Over
20 m
S3200-CN-25-25
(Specify length (m) when ordering.)
Item
Min.
Typical
Max.
Unit
Conditions
Numerical aper-
ture
---
0.21
---
---
Theoretical value
Transmission loss ---
---
3.0 Lf
dB
0.5 km
≤
Lf
λ
= 0.8-
μ
m band
Ta = 25
°
C
3.0 Lf + 0.2
0.2 km
≤
Lf < 0.5 km
3.0 Lf + 0.4
Lf < 0.2 km
Connection loss
---
---
1.0
λ
= 0.8-
μ
m band, 1 location
Transmission
band
500
---
---
MHz · km
λ
= 0.85
μ
m (LD)
Item
Min.
Typical
Max.
Unit
Conditions
Numerical aper-
ture
---
0.28
---
---
Theoretical value
Transmission loss ---
---
3.5 Lf
dB
0.5 km
≤
Lf
λ
= 0.8-
μ
m band
Ta = 25
°
C
3.5 Lf + 0.2
0.2 km
≤
Lf < 0.5 km
3.5 Lf + 0.4
Lf < 0.2 km
Connection loss
---
---
1.0
λ
= 0.8-
μ
m band, 1 location
Transmission
band
200
---
---
MHz · km
λ
= 0.85
μ
m (LD)
Specifications
Length
Model
Summary of Contents for SYSMAC 3G8F7-CLK12-EV1
Page 2: ......
Page 4: ...iv ...
Page 20: ...xx Conformance to EC Directives 6 ...
Page 48: ...28 Applications Precautions Section 1 4 Example CX Programmer Response Timeout Setting ...
Page 68: ...48 Backup Power Supply Wiring Optical Ring Systems Only Section 2 4 ...
Page 74: ...54 Using the C Library Section 3 2 ...
Page 110: ...90 Changing the Data Link Tables with Active Data Links Section 5 5 ...
Page 187: ......