Commands and Responses for the Support Board
Section 6-3
Connection Type: Wired/Optical (response)
Node address (response):
The Support Board’s node address is returned
between 01 and 3E Hex (1 to 62).
Unit address (response):
The unit address set for the Support Board is
returned between 10 and 1F Hex (16 to 31). It is returned even when a unit
address setting error is generated.
Network address (response):
The network address set for the Support
Board in the routing table is returned between 00 and 7F Hex (0 to 127). If the
routing table setting has not been made, 00 Hex is returned.
6-3-5
CONTROLLER STATUS READ
Reads the Controller Link Support Board’s controller status.
Command Block
Response Block
Parameters
Operating status (response):
The operating status of the data links is as fol-
lows:
00 (Hex):
Data links inactive.
01 (Hex):
Data links active.
02 (Hex):
Local data links not active. (The data links are active in the net-
work, but the source node is not participating.)
Status 1, Status 4, Status 6 (response):
Not used by Controller Link.
Always set to 00 (Hex).
0: Wired
1: Optical Ring
N
ot used
Bit
Maximum
N
umber of Supported
N
odes
00: 32 nodes
01: 62 nodes
Transmission Path
0: Token bus
1: Token ring
Note
When optical and optical ring connections are com-
bined, the maximum number of nodes supported
will be gi
v
en as 62 nodes for an optical ring connec-
tion e
v
en if the maximum number of nodes is 32.
7
6
5
4
3
2
1
0
N
umber of send words
0: 1,000 max.
1: 4,000 max.
Command
code
01
06
06
01
00
00
00
00
00
Response code
Command
code
Operating status
Status 1
Status 2
Status 3
Status 4
Status 5
Count 1
Count 8
Status 6
Total 6 bytes
Total 8 bytes
N
etwork
participation
status
Summary of Contents for SYSMAC 3G8F7-CLK12-EV1
Page 2: ......
Page 4: ...iv ...
Page 20: ...xx Conformance to EC Directives 6 ...
Page 48: ...28 Applications Precautions Section 1 4 Example CX Programmer Response Timeout Setting ...
Page 68: ...48 Backup Power Supply Wiring Optical Ring Systems Only Section 2 4 ...
Page 74: ...54 Using the C Library Section 3 2 ...
Page 110: ...90 Changing the Data Link Tables with Active Data Links Section 5 5 ...
Page 187: ......