NX-SIH400
(N4)
I/O power
supply
Non-contact door switch
Non-contact door switch
Non-contact door switch input
Non-contact door switch output
Non-contact door switch input
Non-contact door switch output
Si3
Si2
Si1
Si0
T0
T1
0V
24 VDC
Brown
Blue
Black
White
Brown
Blue
Black
White
Wiring the Reset Switch
Connect the reset switch to the Safety Input Unit (N5).
NX-SIH400
(N5)
Si0
T0
Wiring the Robot
Connect the robot to the Safety Output Unit (N6), Safety Input Unit (N5) and safety relays.
The outputs of the Safety Output Unit (N6) and the inputs of the robot cannot be directly connected,
therefore they are connected through the safety relays.
Use the contact a of each safety relay L1 to L4.
Appendices