9 - 7
9 Setting Up the PROFINET Coupler Unit
NX-series PROFINET Coupler Unit User’s Manual (W623)
9-2 Setting IO Device T
erm
inal
Param
eters
9
9-2-2 Setting the NX Unit C
onfiguration Inform
ation
NX Units
Creating the Unit Configuration Information with the Edit IO Device Terminal
Configuration Tab Page
1
Create a new Sysmac Studio project.
2
Double-click
NX-PNC202
under
Configurations and Setup
in the Multiview Explorer or
right-click
NX-PNC202
under
Configurations and Setup
and select
Edit
.
Name
Settable
Description
Data
range
Default
Device name
Yes
The name of the NX Unit.
---
N* (Where * is a
serial number
from 1)
Model name
This is the model number of the NX Unit.
---
---
Product name
This is the product name.
---
---
Unit version
This is the Unit version of the NX Unit.
---
---
NX Unit Number
This number represents the logical position of the NX
Unit. Numbers are automatically assigned from the left-
most mounting position.
---
---
NX Unit Mounting
Setting
Yes
This setting enables or disables the mounting of an NX
Unit. Refer to
11-2 NX Unit Mounting Settings
11-4 for details on this setting.
Enabled or
Disabled
Enabled
Serial Number
This is the serial number of the NX Unit. You can get
the serial number to set the serial number of the actual
PROFINET Coupler Unit.
---
0
Supply Power/Avail-
able Power [W]
The power that is currently drawn by the NX Units and
the maximum available power supply capacity are
given. This item is for an Additional NX Unit Power Sup-
ply Unit.
---
-/10.00
Power consumption
[W]
This is the power consumption of the NX Units from the
NX bus. This setting applies to Units other than an
Additional NX Unit Power Supply Unit.
---
Refer to the
manual for the
specific NX Unit.
Unit width [mm]
This is the width of the NX Unit.
---
Refer to the
manual for the
specific NX Unit.
IO allocation settings
Yes
These are the IO allocation settings for the NX Unit.
Click the
Edit IO Allocation Settings
button to edit
these settings. You cannot change this setting for Sys-
tem Units.
---
Refer to the
manual for the
specific NX Unit.
Unit operation set-
tings
Yes
These are the Unit operation settings for the NX Unit.
Click the
Edit Unit Operation Settings
button to edit
these settings. You cannot change this setting for Sys-
tem Units.
---
Refer to the
manual for the
specific NX Unit.
Setting the NX Unit Configuration Information
Summary of Contents for PROFINET NX-PNC202
Page 9: ...7 NX series PROFINET Coupler Unit User s Manual W623 CONTENTS...
Page 12: ...Manual Structure 10 NX series PROFINET Coupler Unit User s Manual W623...
Page 32: ...Revision History 30 NX series PROFINET Coupler Unit User s Manual W623...
Page 34: ...Sections in this Manual 32 NX series PROFINET Coupler Unit User s Manual W623...
Page 126: ...6 Installation 6 32 NX series PROFINET Coupler Unit User s Manual W623...
Page 192: ...10 I O Refreshing 10 6 NX series PROFINET Coupler Unit User s Manual W623...
Page 224: ...11 PROFINET Coupler Unit Functions 11 32 NX series PROFINET Coupler Unit User s Manual W623...
Page 260: ...12 Troubleshooting 12 36 NX series PROFINET Coupler Unit User s Manual W623...
Page 268: ...13 Maintenance and Inspection 13 8 NX series PROFINET Coupler Unit User s Manual W623...
Page 274: ...Appendices A 6 NX series PROFINET Coupler Unit User s Manual W623...
Page 275: ...I 1 I I NX series PROFINET Coupler Unit User s Manual W623 Index...
Page 280: ...I 6 NX series PROFINET Coupler Unit User s Manual W623 Index...
Page 281: ......