![Omron PROFINET NX-PNC202 User Manual Download Page 59](http://html1.mh-extra.com/html/omron/profinet-nx-pnc202/profinet-nx-pnc202_user-manual_742786059.webp)
3 - 9
3 Specifications and Application Procedures
NX-series PROFINET Coupler Unit User’s Manual (W623)
3-2 Procedures
3
3-2-2 Details
3-2-2 Details
Procedure
Item
Description
Reference
1
Preparing for
Work
Selecting NX
Units
Select the NX Units and the quantity and types of IO
that are required.
•
• Manuals for the spe-
cific NX Units
Confirming Suit-
ability of IO
Device Termi-
nal Specifica-
tions
Confirm that the following specific restrictions for the IO
Device Terminal are met.
• Number of NX Units
• Design conditions for the NX Unit power supply and
IO power supply
• Installation orientation
•
•
Section 5 Designing
the Power Supply
System
2
Making Hard-
ware Settings
and Wiring the
IO Device Ter-
minal
Installation
Connect the NX Units and End Cover to the PROFINET
Coupler Unit and secure the IO Device Terminal to a
DIN Track to install it.
Wiring
Wire the IO Device Terminal.
• Connect the communications cables.
• Connect the Unit power supply.
• Connect the IO power supply.
• Connect the ground wire.
• Connect the external IO devices.
3
Setting the PROFINET Coupler
Unit’s IO Device Name
Use the third party IO Controller software to set the IO
device name.
9-4 Setting PROFINET
IO Device Name
4
Configuring the IO Device Termi-
nal and Making the Operation
Settings
Set up the IO Device Terminal (create the configuration
and set the parameters) with the Sysmac Studio.
9-2 Setting IO Device
Terminal Parameters
Creating the
Unit Configura-
tion Information
Create the IO Device Terminal configuration information
such as number and order of NX Units, individual NX
Unit information and information about the PROFINET
Coupler Unit.
9-2-2 Setting the NX
Unit Configuration Infor-
mation
Setting the IO
Allocation Infor-
mation
Make the IO allocations for the PROFINET Coupler Unit
and NX Units as required.
9-6 NX Unit IO Alloca-
tion on page 9-27
Unit Operation
Settings
Make the Unit operation settings for the PROFINET
Coupler Unit and NX Units as required.
Setting Unit
Application Data
Create the Unit application data. This step applies only
to Units that have Unit application data.
5
Transferring and Comparing
PROFINET Coupler Unit Param-
eter Settings
Transfer and compare IO Device Terminal settings with
the Sysmac Studio.
9-3 Transferring and
Comparing Settings
6
Setting PROFINET IO Data
Use the third party PROFINET IO Controller software to
set the IO data.
7
Allocate IO Data
Allocate the IO Data to the IO Controller CPU's vari-
ables.
Summary of Contents for PROFINET NX-PNC202
Page 9: ...7 NX series PROFINET Coupler Unit User s Manual W623 CONTENTS...
Page 12: ...Manual Structure 10 NX series PROFINET Coupler Unit User s Manual W623...
Page 32: ...Revision History 30 NX series PROFINET Coupler Unit User s Manual W623...
Page 34: ...Sections in this Manual 32 NX series PROFINET Coupler Unit User s Manual W623...
Page 126: ...6 Installation 6 32 NX series PROFINET Coupler Unit User s Manual W623...
Page 192: ...10 I O Refreshing 10 6 NX series PROFINET Coupler Unit User s Manual W623...
Page 224: ...11 PROFINET Coupler Unit Functions 11 32 NX series PROFINET Coupler Unit User s Manual W623...
Page 260: ...12 Troubleshooting 12 36 NX series PROFINET Coupler Unit User s Manual W623...
Page 268: ...13 Maintenance and Inspection 13 8 NX series PROFINET Coupler Unit User s Manual W623...
Page 274: ...Appendices A 6 NX series PROFINET Coupler Unit User s Manual W623...
Page 275: ...I 1 I I NX series PROFINET Coupler Unit User s Manual W623 Index...
Page 280: ...I 6 NX series PROFINET Coupler Unit User s Manual W623 Index...
Page 281: ......