65
•
Up to 48 items of registered data can be displayed on a screen.
•
If not all of the record data shows on the screen, then use the Down Key to
scroll down.
•
To return to the System Menu, press the Buzzer Key, Up Key, and Down
key simultaneously.
Order of Frequency
Record data is displayed in order of frequency.
No.
200
1
5
Times
( 2)
( 1)
( 1)
Message
Comp. Mal.
Coolant Mal.
Motor Mal.
Of
Number of times occurred.
Screen number
When different messages occur with the same frequency, they are displayed
in order beginning with the lowest screen number.
When there is no display data, the following message will be displayed (for
both order of occurrence and order of frequency).
History Record Not Found
Initializing History Data
To delete history data, first select Maintenance Mode from the System Menu.
The Maintenance Mode Menu will be displayed. Then select “Init. Memory,”
followed by “Init. History.” A message will then be displayed asking for con-
firmation that you want to initialize the history.
Select whether or not the history is to be initialized. If you select Yes, then
initialization will be executed. All recorded history will be deleted. If you select
No, then operation will commence without initialization.
6-2-6
I/O Checks
In the Maintenance Mode Menu, use the Up and Down Keys to move the bar
cursor to I/O Check. When you then press the Enter Key, one of the following
menu will be displayed, depending on the input switch specifications. With
the I/O Check Menu displayed, move the bar cursor to the item you want to
check, and then press the Enter Key.
System Menu and Transmit Mode
Section 6-2
Summary of Contents for NT600M Series