48
Size:
Can be freely set with a rectangle or a circle.
Number:
128 maximum per screen
Display attributes:
Lit, blinking
Guide characters:
Select “yes” or “no.”
Lamps set from the host can be turned on and off by either of two methods:
number designation or bit designation (when there is no direct connection).
For details, refer to the
Host Interface Unit Operation Manual
.
If using a lamp together with a switch, then set the lamp within the switch
frames, of which there are 12 horizontal and 6 vertical.
Example 2: Emphasis
The display of the number defective can be emphasized setting it to light.
Goal
Complete
Defective
1234
600
2
4-10 Graphics Display
Unbroken straight lines (polylines) and circles can be created by the Support
Tool and displayed at the PT. When an RS-232C or RS-422A Interface Unit is
used, the graphics can be displayed by using the terminal function and trans-
mitting commands from the host.
Graphics display positions can be designated in dot units. In cases where
graphics and characters overlap, the graphics will be overwritten (Terminal
Mode). Polylines and circles are both drawn with a width of one dot.
4-11 Special Controls
The status of the NT600M to be controlled from the host during operation.
4-11-1
Backlight ON/OFF
In order to prolong the life of the backlight, the backlight can be turned off by
a backlight-off command from the host when it is not needed during opera-
tion.
Example 1: Usage with
Switch Frames
Designating Display
Positions
Special Controls
Section 4-11