45
4-6
Numeric Displays
A numeral table is stored in the NT600M, and you can display numeric val-
ues from the table at designated positions on a screen. In addition, the val-
ues in the table can be transferred from the host so that they are renewed
each time a new value is transferred. The display positions are set in ad-
vance with the Support Tool.
Example
Screen Registered
Production
Line 1
Weld
Assem
Number
Contents
These contents are transmitted from the host.
When the PC is used as the host, for example, these values will be transferred via the Host
Interface Unit and updated on screen when the contents of the DM Area are changed at the
PC.
Final
Paint
Line 2
# 0
# 1
# 2
# 3
# 4
# 5
# 6
# 7
# 0
1020
# 1
832
# 2
711
# 3
630
# 4
556
# 5
999
# 6
807
# 7
777
to
#255
Screen Displayed
Production
Line 1
Weld
Assem
Final
Paint
Line 2
1020
832
711
630
556
999
807
777
Contents registered to screens by Support Tool:
Numeral table numbers
Display positions (50/screen max.)
Number of digits displayed (whole numbers, fractions)
Character fonts
Sizes of characters displayed
Numeral Table
(Maximum of 256 entries)
Numeric Displays