2-1 Connecting the Host
2-2
2-1 Connecting the Host
This section provides details on the networks for hosts that can be used with NS-series PTs.
2-1-1 Communications
Types and Connection Methods
•
Communications Ports and Methods
All NS-series PTs have two serial ports each. The NS15-TX01
@
-V2, NS12-TS01(B)-V1/-V2,
NS10-TV01(B)-V1/-V2, NS8-TV
@
1(B)-V1/-V2, NS5-SQ01(B)-V1, NS5-SQ
@
1(B)-V2, NS5-
TQ
@
1(B), and NS5-MQ
@
1(B)-V2 each have one Ethernet interface.
A Controller Link Interface Unit can also be mounted to the NS12-TS0
@
(B)-V1 or NS10-
TV0
@
(B)-V1 to enable Controller Link communications. These communications ports and in-
terfaces can be used for the communications methods shown in the following table.
Communications ports
Supported communications methods
Serial port A
1:1 NT Link
1:N NT Links (See note 1.)
For connecting the CX-Designer and for Bar Code Reader input.
Serial port B (See notes 2
and 4.)
1:1 NT Link
1:N NT Links (See note 1.)
For connecting the CX-Designer and for Bar Code Reader input.
Ethernet interface
FINS communications
EtherNet/IP
For connecting the CX-Designer.
Controller Link Interface
Unit (See note 3.)
FINS communications
Data links
Note 1: A 1:N NT Link can be set for either normal or high-speed communications.
Note 2: With the NS5,
EXP. (Expansion) I/F
on the Comm Tab Page in the System Menu settings
can be set to use a communications port in the expansion interface connector. The expan-
sion interface, however, is a future expansion, which cannot yet be used. Always use the se-
rial port B connector. Communications will not be possible on serial port B if the expansion
interface is selected in the System Menu settings.
Note 3: Controller Link Interface Units are compatible only with the NS15, NS12 and NS10.
Note 4: With the NS15, the type of communications (RS-232C or RS-422A) can be selected by set-
ting the DIP switch.
The following table shows the possible combinations of communications methods when serial
ports A and B are connected to the host at the same time.
Using serial ports A and B at the same time
Supported/not supported
1:1 NT Link + 1:1 NT Link
Supported
1:1 NT Link + 1:N NT Links
Supported
1:N NT Links + 1:N NT Links
Supported
•
Converting Communications Type Using RS-232C/RS-422A Converter
OMRON’s NS-AL002 RS-232C/RS-422A Converter can be used to convert the communica-
tions type between RS-232C and RS-422A.
•
Communications Type and Connection Method Combinations
The following table shows the possible connection methods for each communications type.
Summary of Contents for NS - REV 12
Page 2: ......
Page 22: ...20 ...
Page 34: ...1 4 Procedure for Running NS series PTs 1 12 ...
Page 54: ...2 2 Part Names and Functions 2 20 ...
Page 116: ...3 11 RS 232C RS 422A Selector DIP Switch 3 62 ...
Page 144: ...4 4 Recommended Connector Cables 4 28 ...
Page 174: ...5 3 Connecting to Host via EtherNet IP 5 30 ...
Page 246: ...6 11 Verifying Tags 6 72 ...
Page 279: ...Appendix 2 Dimensions A 19 NS5 V1 V2 Cable Connection Dimensions ...
Page 332: ......
Page 333: ......