![background image](http://html.mh-extra.com/html/omron/ns-rev-12/ns-rev-12_setup-manual_744517018.webp)
16
Conformance to Shipbuilding Standards
This product conforms to shipbuilding standards with the exception of the NS15. The
shipbuilding standards have conditions that may make them unusable depending on the
location in which the PT is installed. When using a PT on a ship, be sure to contact your
OMRON sales representative.
Shipping Standards
(NK, LR, ABS, BV, DNV, KR)
Conditions for Use in Locations Other Than the Bridge or Deck
•
The NS-series PT must be installed in a control panel.
•
The control panel must be equipped with an air conditioner.
•
The entire surface of the NS-series PT must be covered with electromagnetic shielding
that is also grounded using conductive tape (e.g., copper tape).
•
Gaps in the door of the control panel must be completely filled or covered with gaskets or
other material.
•
Gaps between the PT and the panel cutout must be completely covered with conductive
tape, such as copper tape, and the PT must be secured using mounting brackets.
Conditions for Use on the Bridge (Class NK Certification Only)
•
The NS-series PT must be installed in a control panel.
•
The control panel must be equipped with an air conditioner.
•
The entire surface of the NS-series PT must be covered with electromagnetic shielding
that is also grounded using conductive tape (e.g., copper tape).
•
Gaps in the door of the control panel must be completely filled or covered with gaskets or
other material.
•
Gaps between the PT and the panel cutout must be completely covered with conductive
tape, such as copper tape, and the PT must be secured using mounting brackets.
•
The following noise filter must be connected to the 0 to 24 VDC power line.
Electromagnetic Shielding
Manufacturer
SEIWA ELECTRIC MFG, Co., Ltd.
Model E09F-100,
E09R13502P
* Electromagnetic shielding reduces the permeability by approximately 50%.
Noise Filter
Manufacturer Cosel
Model TAH-06-683
Summary of Contents for NS - REV 12
Page 2: ......
Page 22: ...20 ...
Page 34: ...1 4 Procedure for Running NS series PTs 1 12 ...
Page 54: ...2 2 Part Names and Functions 2 20 ...
Page 116: ...3 11 RS 232C RS 422A Selector DIP Switch 3 62 ...
Page 144: ...4 4 Recommended Connector Cables 4 28 ...
Page 174: ...5 3 Connecting to Host via EtherNet IP 5 30 ...
Page 246: ...6 11 Verifying Tags 6 72 ...
Page 279: ...Appendix 2 Dimensions A 19 NS5 V1 V2 Cable Connection Dimensions ...
Page 332: ......
Page 333: ......