Appendix 1 Specifications
A-9
Item
Specifications
Using PT serial port and D-Sub 6-pin Using external power supply
Transmission dis-
tance
2 m
15 m
Communications
protocol
No protocol mode
Data format
[STX]
Data (0 to 254 bytes)
[ETX]
Using PT serial port and D-Sub 6-pin Using external power supply
Power supply
5 V
±
5% 250 mA max.
Depends on Bar Code Reader
specifications.
●
Ethernet Specifications (NS15-TX01
@
-V2, NS12-TS01(B)-V1, NS10-
TV01(B)-V1, NS8-
TV@1
(B)-V1, NS5-SQ01(B)-V1, NS5-SQ
@
1(B)-V2, NS5-
TQ
@
1(B)-V2, NS5-MQ
@
1(B)-V2)
Item
Specifications
Conformance standards Conforms to IEEE 802.3 / Ethernet (10/100Base-T).
Transmission medium
2 pair Cat 3 UTP 22 to 26AWG, Cat 5, Cat 5e, Cat 6
Transmission distance
100 m (node-to-hub and hub-to-hub)
Connector
8-pin modular connector
•
Ethernet
Item
Specifications
Network address
1 to 127
Node address
1 to 254
UDP port number
1024 to 65535 (See note 1.)
IP address
0.0.0.0 to 255.255.255.255 (See note 2.)
Subnet mask
0.0.0.0 to 255.255.255.255
Default gateway
0.0.0.0 to 255.255.255.255
IP proxy address
“”(blank), 0.0.0.0 to 255.255.255.255
Conversion table
Node address: 1 to 253
IP address: 0.0.0.0 to 255.255.255.255
Note 1. The default UDP port number is 9600.
2. Do not set the following values for the IP address.
•
Host ID with all bits set to 0 or 1.
(Example:
192.168.21.0
)
•
Net ID with all bits set to 0 or 1.
(Example:
255.255.21.16
)
•
Subnet ID with all bits set to 1.
(Example:
192.168.255.16
)
•
IP addresses that begin with 127. (Example:
127.35.21.16
)
Controller Link Specifications (with NS-CLK21 Controller Link Interface
Unit Mounted)
Item Specification
Communications method N:N token bus
Code Manchester
code
Modulation Baseband
code
Synchronization
Flag synchronization (conforming to HDLC frames)
Transmission path type
Multidrop (bus)
Baud rate and maximum
transmission distance
The maximum transmission distances depends on the baud rate setting as fol-
lows:
2 Mbits/s: 500 m
1 Mbits/s: 800 m
500 Kbits/s: 1 km
Media
Specified shielded twisted-pair cable
2 signal lines and 1 shield
Connections to nodes
PLCs:
Connected via terminal block
Personal computers: Connected via special connector (provided)
Summary of Contents for NS - REV 12
Page 2: ......
Page 22: ...20 ...
Page 34: ...1 4 Procedure for Running NS series PTs 1 12 ...
Page 54: ...2 2 Part Names and Functions 2 20 ...
Page 116: ...3 11 RS 232C RS 422A Selector DIP Switch 3 62 ...
Page 144: ...4 4 Recommended Connector Cables 4 28 ...
Page 174: ...5 3 Connecting to Host via EtherNet IP 5 30 ...
Page 246: ...6 11 Verifying Tags 6 72 ...
Page 279: ...Appendix 2 Dimensions A 19 NS5 V1 V2 Cable Connection Dimensions ...
Page 332: ......
Page 333: ......