3-2 Starting the PT
3-8
Port A and B connection combinations
Expansion Interface Unit
(NS-CA001, NS-CA002,
NS-CLK21)
When a Bar Code Reader and the NT-AL001 are connected to ports
A and B at the same time
Cannot be used
When the CJ1W-CIF11 and C1W-CIF11 are connected to ports A
and B at the same time
Can be used
When the CJ1W-CIF11 and NS-AL002 are connected to ports A and
B at the same time
Can be used
When the CJ1W-CIF11 and NT-AL001 are connected to ports A and
B at the same time
Cannot be used
When two NT-AL001s are connected to ports A and B at the same
time
Cannot be used
When a Bar Code Reader is connected to port A or B
Can be used
When the CJ1W-CIF11 is connected to port A or B
Can be used
When the NS-AL002 is connected to port A or B
Can be used
When the NT-AL001 is connected to port A or B
Can be used
When Bar Code Readers are connected to ports A and B at the
same time
Cannot be used
When the NT-AL001 and NT-AL002 are connected to port A or B at
the same time
Cannot be used
3-2 Starting the PT
Check that the hardware is connected properly, turn ON the power to the PT, and then start
the PT.
Use the following procedure to start the PT.
3-2-1
Operation at Startup
When the power is ON or the PT is reset, the PT will operate as follows:
Indicator lights orange.
Immediately after the power is turned ON, the indicator will light orange.
The file system will be checked and the system recovered if the power was turned OFF
while a file was being written in previous operation, or if the battery capacity was low and
drive safety information from the system program area screen data area could not be saved.
↓
Indicator lights green.
When the system starts properly, the indicator will light green.
If the indicator does not light green, the system programs may be damaged. Contact your
nearest OMRON representative.
↓
Startup message is displayed.
A message about the startup status will be displayed.
If an error occurs, the PT will stop startup procedures and display a message. (Refer to
Sec-
tion 5 Troubleshooting
in the
Programming Manual
.)
If an error occurs that allows startup to continue, a warning will be displayed. When a warn-
ing is displayed, the PT will enter standby state and wait for touch input. Check the message
and then touch the screen. The PT will continue with startup procedures.
Summary of Contents for NS - REV 12
Page 2: ......
Page 22: ...20 ...
Page 34: ...1 4 Procedure for Running NS series PTs 1 12 ...
Page 54: ...2 2 Part Names and Functions 2 20 ...
Page 116: ...3 11 RS 232C RS 422A Selector DIP Switch 3 62 ...
Page 144: ...4 4 Recommended Connector Cables 4 28 ...
Page 174: ...5 3 Connecting to Host via EtherNet IP 5 30 ...
Page 246: ...6 11 Verifying Tags 6 72 ...
Page 279: ...Appendix 2 Dimensions A 19 NS5 V1 V2 Cable Connection Dimensions ...
Page 332: ......
Page 333: ......