![Omron fz5 series Hardware Setup Manual Download Page 78](http://html1.mh-extra.com/html/omron/fz5-series/fz5-series_hardware-setup-manual_742694078.webp)
3 Configuration
3 - 16
Vision System FZ5 series Hardware Setup Manual (Z423)
Connector name
Description
(A)
SD memory card installation
connector
Install the SD memory card. Do not plug or unplug the SD memory
card during measurement operation. Otherwise measurement time
may be affected or data may be destroyed.
(B)
USB 2.0 connector
Connects to USB 2.0. Do not insert or remove during loading or
writing of measurement or data. The measurement time can be
longer or data can be damaged.
(C)
USB 3.0 connector
Connects to USB 3.0. Do not insert or remove during loading or
writing of measurement or data. The measurement time can be
longer or data can be damaged.
USB 3.0 has a high ability to supply the bus power.
Use the Sensor Controller by combining USB 3.0, faster transport
can be realized.
(D)
Ethernet connector
Connect an Ethernet device.
Ethernet port, EtherNet/IP port, and PROFINET port are sharing use.
(E)
RS-232C connector
Connect an external device such as a programmable controller
(F)
Monitor connector
Connect a monitor.
(G)
Parallel connector
(control lines, data lines)
Connect the controller to external devices such as a sync sensor.
(H)
Camera connector
Connect a camera.
(I)
Power supply terminal connector Connect a DC power supply. Wire the controller independently on
other devices. Wire the ground line. Be sure to ground the FH Sensor
Controller alone.
Use the attachment power terminal connector (male) of FH-XCN-L
series.
For details, refer to
5-3 Sensor Controller Installation
in this manual.
(F)
(G)
(H)
(D)
(E)
(I)
(A)
(C)
(B)