![Omron fz5 series Hardware Setup Manual Download Page 214](http://html1.mh-extra.com/html/omron/fz5-series/fz5-series_hardware-setup-manual_742694214.webp)
5 Setup and Wiring
5 - 44
Vision System FZ5 series Hardware Setup Manual (Z423)
When you connect the cable to the Sensor Controller, secure the minimum bending radius of the cable
or cable connector.
• Make sure to tighten all installation screws securely.
• To keep proper air flow, keep the top of the FH Sensor Controller 50 mm or more apart from other
devices. Install the FH Sensor Controller with a clearance of 30 mm on the right and left side, and 15
mm for rear planes. The clearance is required for installing multiple units side-by-side. For the back
mounting, the back-side clearance of 15 mm is nor required.
Mounting the base of the Sensor Controller (Floor mounting)
• Recommended tightening torque: 0.54 N
•
m to 0.6 N
•
m
• The tolerance:
±
0.2 mm
Accessibility for Operation and Maintenance
Installation in a Control Panel
Minimum bending radius
Connector length
Name
Model
Minimum
bending
radius
Connector
length
Camera Cable
FZ-VS3
69 mm
30 mm
Right-angle Camera Cable
FZ-VSL3
Bend resistant Camera Cable FZ-VSB3
Bend resistant Right-angle
Camera Cable
FZ-VSLB3
Long-distance Camera Cable
FZ-VS4
78 mm
42 mm
Long-distance Right-angle
Camera Cable
FZ-VSL4
Clearance: 50 mm
Clearance: 30 mm
Clearance: 15 mm
Clearance: 30 mm
52.9
1
5
59
Four, M4 depth 6.5
10.5
80
22
100