![Omron fz5 series Hardware Setup Manual Download Page 228](http://html1.mh-extra.com/html/omron/fz5-series/fz5-series_hardware-setup-manual_742694228.webp)
6 I/O Interface
6 - 4
Vision System FZ5 series Hardware Setup Manual (Z423)
[Input]
Applicable signals/
• No.4 to 6, 9 to 11 pins:
Connect the COMIN1 terminal when using these signals.
• No.7, 8, 12, 13 pins:
Connect the COMIN0 terminal when using these signals.
[Output]
Applicable signals/
• No.15 to 19 pin, No.28 to 32 pin:
Connect the COMOUT0 terminal when using these signals.
• No.48 to 57 pins:
Connect the COMOUT2 terminal when using these signals.
• No.58 to 66 pins:
Connect the COMOUT3 terminal when using these signals.
[Output]
Applicable signals/
• No.20 to 27 pins:
Connect the COMOUT1 and COMIN0 terminals when using these signals.
Item
Specifications
Input voltage
12 to 24 VDC ±10%
ON current
*1
*1. ON current and ON voltage:
Those mean the current or voltage to turn ON from OFF. The ON voltage value is the potential difference
between COMIN and each input terminal.
5 mA min.
ON voltage
*1
8.8 V min.
OFF current
*2
*2. OFF current and OFF voltage:
Those mean the current or voltage to turn OFF from ON. The OFF voltage value is the potential difference
between COMIN and each input terminal.
0.5 mA max.
OFF voltage
*2
0.8 V max.
ON delay
0.1 ms max.
OFF delay
0.1 ms max.
Maximum frequency response
4 KHz
Item
Specifications
Output voltage
12 to 24 VDC ±10%
Load current
*1
*1. The current value must be the specified load current or lower. Exceeding the specified current value may
cause damage of the output circuit.
45 mA max.
ON residual voltage
2 V max.
OFF leakage current
0.2 mA max.
Item
Specifications
Output voltage
12 to 24 VDC ±10%
Load current
*1
*1. The current value must be the specified load current or lower. Exceeding the specified current value may
cause damage of the output circuit.
45 mA max.
ON residual voltage
2 V max.
OFF leakage current
0.2 mA max.