3 - 97
3 Configuration
Vision System FZ5 series Hardware Setup Manual (Z423)
3
-6 L
CD an
d Cab
le
3
Front View
Rear
The power connection for the Touch Panel Monitor is on the back side of the Monitor.
Connect the 24 VDC power source.
• Keep the power supply wires as short as possible (maximum 10 m).
• If UL recognition is required, use a UL class II power supply.
Regarding installation, do not use the VESA mounting but fix the monitor unit using the board mount-
ing.
Component Names and Functions
Name
Description
(1)
LED indicator lamp (for power)
Lit up green when power is ON.
(2)
LED indicator lamp (for SYNC)
Lit up orange while the video signal is input.
(3)
Power connection terminal
Connect power unit for 24 VDC.
(4)
Video input (RGB)
Video input terminal (RGB)
(5)
MENU button
OSD operating button (MENU button)
(6)
+ button
OSD operating button (+ button)
(7)
- button
OSD operating button (- button)
(8)
AUTO button
OSD operating button (AUTO button)
(9)
VESA mounting hole (M4)
Mounting hole for VESA 75 mm
×
75 mm
Wire
Display section
(1) LED indicator lamp (for power)
(2) LED indicator lamp
(for SYNC)
(5) MENU button
(6) + button
(7) - button
(4) Video input (RGB)
(3) Power connection
terminal
(8) AUTO button
(9) VESA mounting
hole (M4)
M3
(Outside diameter of crimp terminal:
Dia 5.5 mm maximum)
Recommended model
OMRON Corporation-manufactured
S8VS-03024
24 VDC
RGB
Power
supply
24 VDC