![Omron fz5 series Hardware Setup Manual Download Page 266](http://html1.mh-extra.com/html/omron/fz5-series/fz5-series_hardware-setup-manual_742694266.webp)
6 I/O Interface
6 - 42
Vision System FZ5 series Hardware Setup Manual (Z423)
Connection Structure
Cable
FH-VPX-F210
Connector
No.
Connection Destination
Special Notes
CN1
Connect to the parallel port CN1 of the FH Sensor Con-
troller.
Even if you connect the revers CN1
and CN2, Sensor Controller does
not perform.
It is immune to breakdown.
CN2
Connect to the parallel port CN2 of the FH Sensor Con-
troller.
CN3
Connect to the Parallel I/O cable F160-VP.
Parallel connector
(CN1/CN2)
FH controller
Connecting the FZ-VP
and the FH-VPX-
* After the connection, lock it securely.
PLC, terminal blocks or
other products
Power supply used
in the FH controller:
Power supply S8VS
series (24 VDC)
CN1
CN2
F160-VP
FH-VPX-F210
CN3
CN3
10.3
73
500
7.8
47.8
CN1
CN2
50
(Unit: mm)