[Notice] DM Parameter Allocation
For DM parameter area, 100CH are assigned for each Unit number.
For unit No.“0”, DM30000CH to DM30099CH are assigned. (D Unit number x 100 CH)
The Software Switches in DM Parameter Area and the Setting Area of Parameters for Automatically
Setting Data Links (Equality Layout) and their detail are shown below.
Software Switches (D 100 x Unit No.)
0
0
0
0
0
0
0
0
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Polling node/polling node bit
0: Polling node
1: Polled node
CPU Bus Unit PLC Setup
Initialization
0: Not initialize CPU Bus Unit
PLC Setup
1: Initialize CPU Bus Unit
PLC Setup
Wired Network 62 Node
Enable Bit
0: 32 nodes max.
1: 62 nodes max.
Data Link status
Storage format
0: 8-bit format
1: 4-bit format
Data Link mode
000: Manual
001: Automatic, equality layout
101: Automatic, 1:N allocation
Data Link Start Bit
Start: Changed from OFF
to ON or set to ON
when power is
turned ON.
Stop: Changed from ON
to OFF.
* 0: Always set to 0.
Leftmost digit of data link start word of
area 2 (BCD)
00
First data link status word (BCD)
Number of send words per node of area 2 (BCD)
Area 2 type
Rightmost 4 digits of data link start word of area 2 (DM area) (BCD)
Number of send words per node of area 1 (BCD)
Area 1 type
Area 1 data link start word (BCD)
15
8
7
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
ー
ー
62
61
60
59
58
57
56
55
54
53
52
51
50
49
+8
+9
+10
+11
Nodes to participate in the
data links
The value assigned
indicates whether the node
is to participate in the data
links.
Participate: 1
Not participate: 0
BCD: Set the value as binary-coded decimal.
Parameters for Automatically Setting Data Links with Equality Layout: D 100 x
(Unit No. + 1 to + 11)
+7
+6
+5
+4
+3
+2
+1
2-1 Controller Link Unit
CJ1W-CLK21-V1
Summary of Contents for FB LIBRARY -
Page 1: ......
Page 14: ...2 1 Controller Link Unit CJ1W CLK21 V1...
Page 23: ...2 2 DeviceNet Slave DRT2 Series DRT2...
Page 31: ...2 3 Position Control Unit CJ1W NCF71...
Page 42: ...2 4 Position Control Unit CJ1W NC113 133 213 233 413 433...
Page 49: ...2 5 Position Control Unit CS1W NC113 133 213 233 413 433...
Page 57: ...2 6 Inverter 3G3MV A2 AB A4 3G3RV A2 A4...
Page 71: ...2 7 Servo Driver R88D WT WT H WT HL R7D AP H AP L...
Page 84: ...2 8 RFID ID Sensor V600 H...
Page 95: ...2 9 Vision Sensor F160 C10...
Page 105: ...2 10 2D Code Reader V530 R2000 R160 R150V3...
Page 118: ...2 11 Smart Sensor ZX SF11 ZX LD40 ZX LDA11 N...
Page 129: ...2 12 Temperature Controller E5ZN 2...
Page 139: ...2 13 Temperature Control Unit CJ1W TC001 101 003 103 002 102 004 104...