2-3. Communication Setup 1
Configure the communication setting as shown below:
Set items marked by red underscores to values as shown above.
Then connect PLC online and transmit the PC system setup.
Vision Sensor Setting
Vision Sensor Setting
None. Use with the default factory setup.
Communication Mode
Free Transmission Mode
Communication Speed
38400 bps
Data Bit Length
8 bits
Parity Check
None
Stop Bit
1 bit
Start Code
None
End Code
End code setting: 0x0D (CR)
PLC Setting
PLC Setting
Activate CX-Programmer,
then click PC System Setup
icon
PC System Setup
screen pops up.
2-9 Vision Sensor
F160-C10