![background image](http://html1.mh-extra.com/html/omron/ej1-07-2008/ej1-07-2008_operation-manual_743567135.webp)
116
Examples Using CompoWay/F Commands
Section 6-3
Command Details
(Operation 2)
[CMND S D C]
Response Details (Operation 2)
S
0: 2801 hex
Command code
+1: 0036 hex
DeviceNet Communications Unit node address = 00
hex
Service code = 36 hex
+2: 0086 hex
Class ID = 0086 hex
+3: 0001 hex
Instance ID = 01 hex
+4: 0000 hex
TC2 communications unit number = 00 hex, sub-
address (fixed) = 00 hex
+5: 0001 hex
SID (fixed) = 00 hex, MRC = 01He x
+6: 01C0 hex
SRC = 01 hex, variable type = C0 hex
+7: 0003 hex
Read address = 0000 hex (2 bytes)
+8: 0000 hex
Bit position (fixed) = 00 hex, No. of elements = 00
hex (2 bytes)
+9: 0100 hex
No. of elements = 01 hex
D
D01220:
First response storage word
C
0: 0013 hex
No. of command data bytes
+1: 0013 hex
No. of response data bytes
+2: 0000 hex
Remote (destination) network address = 0
+3: 3FFE hex
Remote (destination) node address = 3F hex
Remote (destination) Unit address FE hex (10 hex is
also possible)
+4: 0000 hex
Response required, communications port No. = 0,
No. of retries = 0 hex
+5: 0064 hex
Response monitoring time
0: 2801 hex
Command code
+1: 0000 hex
End code (FINS)
+2: 000D hex
No. of bytes received
+3: 00B6 hex
Node address = 00 hex, service code = B6 hex
+4: 0000 hex
TC2 communications unit number = 00 hex, sub-address
(fixed) = 00 hex
+5: 0001 hex
End code (CompoWay/F), MRC = 01 hex
+6: 0100 hex
SRC = 01 hex, end code (FINS-mini) = 00 hex (2 bytes)
+7: 0000 hex
End code (FINS-mini) = 00 hex, read data = 00 hex
(4 bytes)
+8: 0002 hex
Read data = 0002 hex
+9: 4000 hex
Read data = 40 hex (rightmost 00 hex is ignored)
Summary of Contents for EJ1 - 07-2008
Page 3: ...iv...
Page 19: ...xx...
Page 33: ...14 Initial Temperature Controller Settings Section 1 4...
Page 53: ...34 Wiring the Temperature Controllers Section 3 4...
Page 101: ...82 Ladder Programming Examples Section 4 6...
Page 143: ...124 Sending Explicit Messages Section 6 5...
Page 155: ...136 Message Communications Characteristics Section 7 2...
Page 163: ...144 Maintenance Section 8 2...
Page 189: ...170 Allocation Numbers for Configurators Manufactured by Other Companies Appendix B...
Page 197: ...178 Index...